AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 398

Support for UOM conversions

Being able to specify a UOM that is not the default UOM and having the value returned converted in all functions Note: This was previously Enhancement 25182OSI8
Guest over 3 years ago in AVEVA™ PI DataLink™ / Functions 2 No status

PI OPC UA Connector to write Bad Input/Configure

PI OPC UA Connector to write Bad Input/Configure when the respective NodeId is no longer available in OPC UA Server.
Fnu Safdar 28 days ago in PI Connectors / PI Connector for OPC UA 0 No status

Extend PI Data Archive time zone setting support

Currently PI DataLink allows you to select the PI Data Archive time zone setting however this setting only applies to data items or expressions that contain either a PI point or a PI AF attribute that is a PI point data reference. If the data item...
Guest 6 months ago in AVEVA™ PI DataLink™ / Settings 0 No status

Auto-Update enabled by default on Excel startup

Add a setting to turn on the "Auto-Update" button on Excel startup automatically. Note: This was previously Enhancement 26678OSI8.
Guest over 3 years ago in AVEVA™ PI DataLink™ / Settings 1 No status

Time Zone Specification to Represent Data in

Letting the customer specify the time zone in which to represent the data would be a nice enhancement. Note: This was previously Enhancement 2729OSI8.
Guest over 3 years ago in AVEVA™ PI DataLink™ / Settings 10 No status

Ability for PI Connectors to create future data point

Add the ability for PI Connectors to create future data point. This is especially useful for the PI Connector for UFL. The current workaround is to manually create the point as a StoredValues=FutureData.
Gabriel Verreault over 3 years ago in PI Connectors / General 0 No status

Enable setting tag attributes in UFL Connector

UFL Connector should have ways to set tag attributes. There should be way to set the default compression and exception settings and also other tag attributes like point and data security.
Guest over 3 years ago in PI Connectors / PI Connector for UFL 3 No status

OPC UA: Set PI Tag Zero and Span Based on OPC UA Range

For OPC UA Analog Items, the OPC UA standard mandates an EURange property and an optional InstrumentRange property. These Range properties contain a Low and High field.The PI Connector for OPC UA should have an option to use either of these Ranges...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

OPC UA Historical data recovery

The PI OPC UA connector can manage historical data recovery when connection is lost between the OPC UA server and the connector, but if the connection problem is between the OPC UA server and the data source on field, when connection is recovered ...
JavierCastane over 3 years ago in PI Connectors / PI Connector for OPC UA 4 No status

Need to start/stop individual data sources

When going in the PI Connector Admin page in the data sources page, we cannot start/stop individual data sources listed when there is more than one. To stop one you need to stop all the data sources listed.
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 2 No status