To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 4863

User should be able to select multiple checkboxes in the backfilling / recalculation status. window.

Please refer the screenshot of existing window. There is no option to select multiple checkboxes. If user want to cancel multiple backfilling process which are queued (it was more than 50), then the cancellation option is not available to stop thi...
Guest over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Batch interface to AF connection health monitoring tag

Having a health tag for batch interfaces which monitors the connection status between the interface and its corresponding AF server. This way, users can be informed if there are any issues with the interface creating event frames on AF.
Guest 12 months ago in PI Interfaces / Batch Interfaces 0 No status

PI Manual Logger Web でのエラー境界線のカスタマイズ

グリッド ビューでは、オペレーターは制限列の薄い黄色のエラー境界線を確認するのが困難です。何かが制限違反であることを簡単に確認できるように、エラー境界線の太さと色をカスタマイズする方法を希望します。
Guest 6 months ago in AVEVA™ PI Vision™ / Manual Data Entry / PI Manual Logger 0 No status

PI マニュアル ロガーWebのツアー スケジュール設定

PI Manual Logger PC では、スケジュールに従ってツアーを実行するように設定できます。これにより、アプリケーションがツアーを最も近い時間で実行するのではなく、ツアーの実行時間を設定することができます。 PI Manual Logger Web では、ツアー スケジュール設定は考慮されません。定期的なツアー スケジュールに従って、PI Manual Logger Web にツアー実行の機能を追加を希望します。
Guest 6 months ago in AVEVA™ PI Vision™ / Manual Data Entry / PI Manual Logger 0 No status

Ability to monitor changes in interface configuration.

Need to know when the interface configuration was edited and which parameter was changed.
Mohammed Qasim Asghar almost 1 year ago in PI Interfaces / General 0 Declined

Drag and drop display(s) into folders

Ability to directly on PI Vision drag displays into folders to move them. Furthermore, select multiple displays and drag & drop them into a folder.
Carlo Villarreal almost 2 years ago in AVEVA™ PI Vision™ / Administration 0 No status

Use digital states in AF instead of Enumeration sets

A customer thinks it is unreasonable to require all customers to recreate the linkage of a new attribute to a Enumeration Set that is a copy of the Digital State Set for the attribute’s linked PI tag. There should really be an Attribute “Value Typ...
Audrey Finken almost 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Option to not have Value Retrieval Method and TagTot "fill in the gaps"

When taking a Total using Value Retrieval Method (configured in AF Attribute) or using TagTot (an AF Analytics function), PI will "fill in" gaps in the data. For instance, if you have a Float32 tag that is reading good for half of the day and then...
taterhead247 almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Documentation of EDS Modbus TCP Adapter needs to be updated on removed 32-bit register support for Modbus TCP Adapter

Challenge: The current version of PI Adapter for Modbus TCP does not any longer support 32-bit Holding/Input registers as this is outside of the Modbus specifications. However, in some cases, 32-bit register values have to be read from 16-bit regi...
Hans-Otto Weinhold about 1 year ago in Edge Data Store / Ingress 0 Planned

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status