Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Trend Cursor: Remove parallel lines "bracketing" the point of interest when placing trend cursors

When applying a cursor to a trend there are two "bracket" lines surrounding the specific point of interest. When placing multiple cursors on a trend this can get quite confusing as to which vertical line is the desired point of interest. Please
Guest almost 4 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 2 No status

PI Interface for Performance Monitor - Parameter to Ignore Device Status for Failover Pairs

When machines being monitored by the Performance Monitor Interface go offline, PerfMon Interfaces in failover pairs can thrash due to the health point device status for the machines not being resolved after a failover event. (The machine is still ...
Joshua Weishaar 9 months ago in PI Interfaces / Other Interfaces 0 No status

Make PI Vision Calculation not affected by PI Point or AF Attribute renaming

When a PI point is renamed, any symbols that reference it directly continue to work. However, calculations that depend on the renamed PI point stop functioning. Please update the calculations so they remain functional even after PI points or AF at...
marc.cote 9 months ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Enable Adapter for OPC UA to use the Pub/Sub method

Pub/Sub is proposed to be a more efficient and scalable method of transferring data using OPC UA. Allowing the adapter to access data in this way would increase the options for data collection, and allow the OPC UA adapter to be used in many more ...
Mike Horrocks over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Notifications automated emails need to display all receivers of the automated emails from the PI Notifications application, not just the singular user (me in this case).

PI Notifications automated emails need to display all receivers of the automated emails in the list of emails that the automated email was sent to. It is very important for the user (or receiver of the automated PI Notification email) to understan...
Phil Jones about 3 years ago in AVEVA™ PI Server / Notifications 1 No status

Allow Select All of search results with filter criteria (very simple GUI change)

When performing a search in PI System Explorer, you can perform a "Select All" on the search results by left clicking on an empty gray section at the top. This section disappears after applying filter criteria, effectively removing the "Select All...
Greg Malek 9 months ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

interpolated datasets

Archived dataset is not required
Guest over 1 year ago in PI to CONNECT / General 0 No status

Consistent colour palettes across symbols and multi-states

Currently, the colour palette and swatches provided by multi-stating doesn't have the same selection as for the symbols. Trying to have a consistent colour scheme is hampered by this. For example, the default blue (3f7faa) used in trending is not ...
Mike Horrocks about 3 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 0 No status

Time range configurable to attribute value

Allow the time range (either start time or end time or both) in Pi Vision to reference an attribute value. This would allow data to dynamically update according to an event. For example, I want to see a list of batch information (start time, end t...
Guest over 2 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

PI Interface for Ramp Soak Simulator Data - Update Time Period To Seconds

To simulate data using the PI Interface for Ramp Soak Simulator Data, the ExDesc of the PI Point needs to be of the format: (period, end_value) period is the time in minutes. end_value is the value for the tag at the end of the phase period. Cur...
Mohammed Qasim Asghar over 1 year ago in PI Interfaces / Other Interfaces 0 No status