To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 3538

More options when searching for PI Points

During a Lighthouse project a customer noted that they have a number of points in their data archive that are no longer on scan. It would be helpful, then, if the PI Point Search facilities in PI to CONNECT allowed use of the ‘scan on/off’ flag so...
Guest about 3 years ago in PI to CONNECT / General 0 No status

Manual recovery

Please introduce manual recovery option within OPC UA Interface because if we have to go back in time to recover data then there is no option to do a manual recovery.
Navanita about 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

PI EMDVB - Set Procedure start time to match first Unit Procedure start time

Currently, when an operator adds a new batch to the DeltaV Batch List, that "creation" action starts a new EF Procedure. But the batch might sit in that list for a long time before the Unit actually starts processing it. This leads to a huge empty...
Guest over 1 year ago in PI Interfaces / Batch Interfaces 0 No status

Allow Line Connection/Elbows

When adding line connectors between icons please allow corners in the line i.e. voltage lines. When adding lines with corners, they have to be edited individually on each segment. So if the color needs to be changed or a state change needs to be a...
ebergman about 3 years ago in AVEVA™ PI Vision™ / Authoring Displays 0 No status

PI Ecuation in AF Analyses accept starttime and endtime from client

584 / 5.000 Processbook and Datalink allow dynamic starttime and endtime in PI Equations.For example, the TimeEq function allows you to obtain the starttime and endtime of the client.Our PI Vision users would find it very useful to have that featu...
Guest about 3 years ago in AVEVA™ PI System Access (PSA) / PI AF SDK 0 No status

Simpler performance analysis service statistics review directly in AF Explorer

Consider implementation performance analysis service statistics in AF Explorer which is now performed in a complicated way by exporting data to Excel, rearranging and viewing in a pivot table. It would also be useful to be able to retrieve that da...
igreguri about 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Make "In" operator compatible with arrays within AF Analysis

We have many calculations following this basic pattern - take recorded values of one attribute, apply a filter (using FilterData), then retrieve values of a second attribute at the filtered timestamps of the first attribute. Currently, we cannot r...
Gregory Malek over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Allow sending data to Apache Kafka target in XML Format using the PI Integrator for Business Analytics

It might be necessary to send data to Apache Kafka target in XML, because Consumers might need the data in XML format (altough it can be considered outdated). This would avoid the necessity to convert the data from JSON to XML as an additional ste...
Julian Baur over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Overload the Convert function to allow a input UoM and output UoM for unitless values

For unitless values you can assign a unit of measure by using the Convert() function. To further convert this to another UoM in the same class you need to nest another Convert() function. For example, Convert(Convert(3600, "s"), "h")) It would sim...
Mike Horrocks over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Replace "https://techsupport.osisoft.com" in PI DataLink's About window

The link redirects to myOSIsoft. The link should be revised so that it does not redirect and possibly so that it leads to a different page instead. Either that or the link can be eliminated entirely.