To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 404

OPC UA: Set PI Tag Zero and Span Based on OPC UA Range

For OPC UA Analog Items, the OPC UA standard mandates an EURange property and an optional InstrumentRange property. These Range properties contain a Low and High field.The PI Connector for OPC UA should have an option to use either of these Ranges...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

OPC UA Historical data recovery

The PI OPC UA connector can manage historical data recovery when connection is lost between the OPC UA server and the connector, but if the connection problem is between the OPC UA server and the data source on field, when connection is recovered ...
JavierCastane over 3 years ago in PI Connectors / PI Connector for OPC UA 4 No status

Egress via AF SDK

Please add AF SDK Egress as an additional optional egress component. This would be very helpful for customers who are using the adapters, but keeping the PI Server on-premise. The adapters are relatively light-weight services; however, the “cost” ...
sahilp 4 months ago in AVEVA™ Adapters / General 0 No status

Need to start/stop individual data sources

When going in the PI Connector Admin page in the data sources page, we cannot start/stop individual data sources listed when there is more than one. To stop one you need to stop all the data sources listed.
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 2 No status

Give the ability upload different Tag Naming files in DCM / OPC UA Connector

When uploading a "Tag Naming" file in DCM, this file completly replace the existing Tag naming. It mean that a Tag naming file must be done for all datasources within one connector. It would be a lot more easy when dealing with a large number of t...
Fred_EYRAUD over 3 years ago in PI Connectors / PI Connector for OPC UA 2 No status

PI Connector Relay support write modes

While writing data to PI through the connector relay there seems to be no option to control the write mode . E.g."[-109] Value at This Time Already Exists" is shown in the logs if the archive already contains an event with the same timestamp. The ...
Guest over 3 years ago in PI Connectors / General 2 No status

Create child Event Frames

UFL connector can create child element using StoreElement function. it should be useful to extend functionality to event frames on function StoreEventFrame
Carlo Pedroli over 3 years ago in PI Connectors / PI Connector for UFL 0 No status

PI OPC UA Connector - point attribute based configuration

We are just starting the first tests with PI OPC UA Interface. We notice that the classic method of tag configuration, known from the interface, is no longer possible. This is probably due to the connector concept. Unfortunately, this does not fit...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...
Timur Eroglu almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Sampling/Publishing Interval parameters to be part of Data Selection description

When configuring the AVEVA Adapters in general, we would find more convenient to be able to define the ‘Sampling Interval’ and 'Publishing Interval' parameters inside the ‘Data Selection’ configuration per each data stream. For instance, when desc...
Christian Leroux over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status