Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 4929

Data Retention configuration for EDS SDS

We have no information regarding data retention. This could be clarified. Data retention should be better configurable as of now, only the stream size can be configured just by estimation. Provide a sizing and calculation tool for Edge Data Store ...
Hans-Otto Weinhold 11 months ago in Edge Data Store / Historian 0 No status

Disable intellisense ("autofill") feature in PSE

When I’m creating a new EF and I start to type the PiPoint name for the analysis, Pi tries to make my life easier by shortlisting the possible pipoints based of what I am typing. i.e if I type “Temp” a popup will appear with a list of pipoints tha...
Dong Yeow Wong almost 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

About PI Vision Bar Graph Symbols

If you assign a PI Point with a value that exceeds the upper and lower limits with a bar graph symbol, an arrow mark will be displayed, but I would like a function to turn this on and off.
Guest almost 2 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Implement similar functionality as the /ta flag from the OPC DA interface

Using the OPC UA connector there is no equivalent to the /ta flag in the OPC DA interface, which ensures when a value significantly changes in a short time period that it does not interpolate. The current work around of setting the Step attribute ...
caffreys_col 11 months ago in PI Connectors / PI Connector for OPC UA 0 No status

Zooming in on plot results in visual change in binary Calculation from always 0 to sometimes 1 . Bug?

I implemented a PI Vision Calculation to implement a binary trend that shows a '1' spike when a value suddenly changes. My goal was to identify at a glance sudden changes for long x vs time plot time durations (those events happen to be very rare)...
Guest almost 2 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 1 No status

BUG: GE HABConnect with BitContainers

I have a case that was closed in 2017, where someone provided a workaround executable for the Interface that fixed the issue. I am assuming they were able to detect a bit container field if the MASK was set for the pitag, but unsure. However after...
Guest almost 2 years ago in PI Interfaces / General 0 No status

Improve Search Performance when using both Attribute Name and Description

When the AFAttributeSearch(AFDatabase, String, String) AF SDK method is used, the AF Server will produce queries that may result into suboptimal SQL Server execution plans when using the default pageSize parameter for searching including attribute...
Guest 11 months ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Table/Bulk PI Tag Editor for PI System Explorer

Allow you to right-click on an element in the tree and and pop-up a box that searches for all PI Point DR attributes in this element and down the tree from this element with the path, the value, and the configuration string. Supported by a search ...
Martin Bryant almost 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Matthew Kishe almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration

Option to hide header row in results from Explore Events function

When pulling in results from searches in the Explore Events function, the option to hide the results header row would be beneficial when working with multiple attribute filter values in the same sheet
Guest almost 2 years ago in AVEVA™ PI DataLink™ / Events (EF) 0 No status