Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 3535

Enable suppression of certain error messages in HABConnect interface

Related to this article: https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=000031389 I may have keys that are all spaces, and this may result in constant logging of the following error upon every database refresh (determined by...
Paul Kim over 3 years ago in AVEVA™ PI Server / General 0 No status

General Feedback

Hello, I don't see any roadmap from OSIsoft/AVEVA for the currently supported products. Looks like OSIsoft decided collect SRP for the existing OSIsoft software products and promote only the AVEVA products. Thanks, Subburaman Sankaran
Guest over 3 years ago in AVEVA™ PI Server / General 0 No status

Allow data update for future PI Points in PI OPC DA Server

When a future pi point is published in the OPC DA server current value matches PI DA current value but it does not update new events on the PI DA You need to create another group in an OPC client or close the connection and reconnect to see new va...
asanzacedo over 3 years ago in AVEVA™ PI Server / General 0 No status

PI Interface for OPC DA and VT_ARRAY|VT_BSTR datatype

PI Interface for OPC DA has a plugin called "Time Array" to manage numerical arrays but string arrays are not supported. It would be a good improvement to develop this feature for string arrays.
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Limit the tour list display in PI Manual Logger Web Home screen

When there are many tours for a group of users, the tour list becomes very long, user need to scroll all the way down to the bottom to reach the recent Tour Runs or new Tour Run button. Suggest to give option not to display all the tours or limit ...
Guest over 3 years ago in AVEVA™ PI Vision™ / Manual Data Entry / PI Manual Logger 0 No status

Provide the user ability to select Event Frame templates during the Batch to Event Frames Migration

During the Batch to Event Frames Migration, all migrated Event Frames are created with 'Migrated' templates (i.e. PIBatchMigrated, PIUnitBatchMigrated, etc.). I would like the ability to pick and choose what templates migrated Event Frames are cre...
Ellery Murdock over 3 years ago in AVEVA™ PI Server / Data Archive 0 No status

Optimize the storage and retrieval of digital tags

Given that the archive file format is proprietary, this suggestion is me shooting in the dark. Disk compression compresses archive files very well, and my guess is that most of this compression occurs on the digital tags, since the number of poss...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / Data Archive 7 No status

Have an option to use step interpolation to the previous event

When the Step attribute of a PI Point is "on", PI assumes that a value is constant until the next event, which works well in most cases. For PI Points that track rolling averages, rolling totals, real-time derivatives of totalizer tags with respe...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / Data Archive 1 No status

Change Flat Data to No Data if PI Interface to PI Server Connection is lost

Problem: iIf PI Interface disconnected from PI Server, PI Point will show flat data until connection up not No data or Disconnected Propose Solution: Pl Server have ability to change flat data to no data if PI interface disconnected from PI Serve...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 1 No status

Restore Write access to Module Dabase after uninstalling AF link

MDB to AF synchronisation is not needed anymore and new installation of data archive are free to not install it. Existing installations must maintain this link in order to allow PI-ACE to function properly and add new context. PI-ACE cannot be rep...
alouette_pelr over 3 years ago in AVEVA™ PI Server / Data Archive 0 No status