Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 513

Allowing the MQTT adapter to set PI Point attributes during the creation process

we're interested in having the ability to configure the zero, span and some other points parameters during the creation of the PI points. currently when points are created. they're defaulting to zero=0 and span=100. while also displaying Boolean p...
Guest 10 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Allow the data type of PI Points to be set manually with PI connector for OPCUA

[Background]We know that when use PI Connetor for OPCUA, the data type of the PI Point is synchronized with the OPC server settings. But we would like to set deferent one.e.x.) -Datatype of OPC Server tag : "String" -Data type wanted to be set for...
Guest over 1 year ago in PI Connectors / PI Connector for OPC UA 0 No status

Ability to disable file renaming for AVEVA Adapter for Structured Data Files or PI UFL products.

The pharma industry has to abide to GMP regulations, in this scenario, the original files should not be modified or renamed. It would be good to have an end to end solution with PI System products instead of making copies of the original file.
Alex Santos over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 0 No status

Include [optional] unit of measure in the data selection configuration.

Some data sources do not provide a unit of measure. It would be useful to be able to specify the unit of measure as part of the data configuration so that this information is provided to EDS/PI/ADH through the data flow.
Mike Horrocks over 1 year ago in AVEVA™ Adapters / General 1 No status

Native Python connector for Linux

I'm a Lead Data Scientist. I've built the MLOps pipeline for Machine Learning (ML) models. To train a model, I need at least 2-3 years of data at high frequency. While the entire data sciences community relies heavily on Python, I'm amazed to see ...
Guest 11 months ago in PI Connectors / New PI Connector Request 0 No status

Allow the BACnet Connector to handle responses with an LVT that does not match the request

Currently the BACnet Connector expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Connector cannot parse the data in the response. For example: Request from Connector, LVT=1 Re...
Nico Cha almost 2 years ago in PI Connectors / PI Connector for BACnet 0 No status

Separated output folder for different data source

I am interested to be able to configure for each data source separately output folder where processed data files are stored. Currently, all processed data files are moved to one OUTPUT folder and afterwards zipped. I would like to have this functi...
Guest almost 3 years ago in PI Connectors / PI Connector for UFL 0 No status

PI System Connector: Allow subset of event frames to be replicated

Currently you only have the ability to replicate ALL event frames and only if you want to replicate the entire AF database. We have one main AF database with many different types of event frames; however we do not want to replicate them all. It wo...
Rebekah_Wilson almost 2 years ago in PI Connectors / PI System Connector 1 No status

host adapter(s) as a service

SaaS solution for customers with benefits thereof.
Guest almost 2 years ago in AVEVA™ Adapters / General 1 No status

Support of EEC (Elliptic Curve Digital Signature Algorithm ) Certificates

Make the Connector, DCM and Relay support EEC (Elliptic Curve Digital Signature Algorithm) Certificates in future versions. Admin Certificates can be exchanged manually usinmg netsh, but the usage of RSA encrypted certificates is required here.
Julian Baur almost 3 years ago in PI Connectors / General 0 No status