Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Analysis timerule option: Add a possibility to make the timerule conservative. Emit calculation events only if the snapshot time of all inputs are more recent than the planned calculation time.

Now the TimeRules Natural and Periodic emit events to the Data PIPE in case NATURAL: an event is received by one of the selected inputs case PERIOD: when a certain timespan elapse.Both method doesn't take into account that some input of the analys...
Marco Blokdijk over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Be able to choose custom format for plots in displays directly in the PI Processbook to PI Vision Migration Utility

When migrating displays, plots display the tag names by default. Setting the "Legend" option under "Custom Format" solves it, but you need to do it manually, one by one. It would be very useful to be able to choose plots' formatting during the mig...
Guest over 2 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 0 No status

Enable the ability to use the UserInt1 to propagate PI to PI APS source tag name changes to the target if source collective Data Archive-level failover is configured

UserInt1 attribute contains source point ID. (Illegal configuration if source Data Archive-level failover is configured.) Source tag mapping by point ID is not compatible with Data Archive-level failover.
Guest over 2 years ago in PI Interfaces / PI to PI Interface 0 No status

Better support of IP21 OPC UA Server with PI Adapter for OPC UA

We have been using the PI Adapter for OPC UA in its current version to collect data from IP21 OPC UA Server during a lighthouse project. However, the configuration was a bit cumbersome since the OPC UA Server of AspenTech uses an opaque mechanism ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Make the ICU maximize button work.

Clicking the maximize button in the ICU makes it take up the whole screen but the fields remain the same size. If the fields resized as well, it would make reading and entry in some of the smaller fields easier.
rphilp1 over 2 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 1 Declined

Add severity as a notification trigger criteria

Sometimes we have cases where we want to create the event but do not send a notification if the severity is low. I think it would be beneficial if we could add the severity as a criteria for notifications, that way we can choose at which point the...
Carlos Castro over 2 years ago in AVEVA™ PI Server / Notifications 0 No status

Update 'Modified date' of an event frame when an attribute is filled in manually (for example with reason code)

At this point, only the modified date of an event frame is updated when the event frame is created or when a backfill or recapture is performed. For transferring data to a data lake or warehouse, it would be very useful to see which event frames c...
Bart Van De Gehuchte over 1 year ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

déplacer le curseur avec les flèches du clavier, pour être plus précis

Avoir la possibilité de déplacer le curseur sur les courbes avec les flèches du clavier, au lieu de la souri et pouvoir supprimer le curseur
Guest over 2 years ago in AVEVA™ PI Vision™ / Navigation 0 No status

Ability to find the EFGEN configuration server name and interface ID for Event frames

It would be great if we can know from which machine EFGEN interface are configured and the corresponding EFGEN interface Id for a particular event, so it will be easy to troubleshoot the issues occurring in event frame generation.
PradeepKumar Logandurai over 1 year ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Option to color the graph by tag/alias instead of giving every tag the same 'event color' (event comparison display)

This will make it easier to see data variations for a specific tag. This was possible in processbook with the color scheme set to tag/alias.
Guest over 2 years ago in AVEVA™ PI Vision™ / Event Comparison Displays 0 No status