Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 4925

PI to Connect (formerly Pi to OCS) agent needs to be collective aware

The PI to Connect agent is not collective aware. Instead, only a single archive can be mapped to the agent. Please allow the PI to Connect agent to utilize collectives. This increases the system's overall resiliency.
Devin over 2 years ago in PI to CONNECT / General 2 Future consideration

Display Utility options for duplicate displays

I would like the PI Vision Display Utility to give me a warning and options if I try to move displays to a target database that has existing displays with the same names. This would avoid unintentionally creating duplicate displays with the same n...
Guest over 2 years ago in AVEVA™ PI Vision™ / Display Management / Displays Page 5 No status

UFL Timezone Conversion

Supported timestamps are currently limited to Local or UTC timezones. Data sources may not be configurable to provide timestamps in supported formats. There currently exists no robust or simple way of converting between timezones using the UFL...
Guest over 2 years ago in PI Connectors / PI Connector for UFL 5 Declined

Enable setting tag attributes in UFL Connector

UFL Connector should have ways to set tag attributes. There should be way to set the default compression and exception settings and also other tag attributes like point and data security.
Guest over 2 years ago in PI Connectors / PI Connector for UFL 3 No status

A progress bar during data discovery

It would be great to have some indication of how far the Connector is through the data discovery process.
David Scott 3 months ago in PI Connectors / PI Connector for OPC UA 0 No status

Have programmatic API and framework kit for Integrators

Many partners we work with would like to be able to configure views and data output from PI Integrator for BA directly from within their Analytics tools. This could also allow for better integration with third party analytics tools and open an OEM...
Guest over 2 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Create a programmatic access layer

Customers have been using DLResize in the VBA pidldialogs.xla project which is unsupported. It would be nice to create a programmatic access layer so that things such as DLResize can be done in a supported way. It would also be helpful to have pro...
Guest over 2 years ago in AVEVA™ PI DataLink™ / Programming 1 Declined

PI Adapter for OPC UA Array Support

As a PI System Administrator, I would like for the PI Adapter for OPC UA to support array data types from the OPC UA Server. A large amount of our data may be contained within arrays on our OPC UA Server, so we would not currently be able to colle...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 6 No status

Allow Definition of Point Attributes via OMF to PI Web API

When creating containers via OMF the PI Points are created with default Point Attributes - if these need to be changed it is a manual process to subsequently change the attributes appropriately. As OMF solutions can be easily deployed it would be ...
Guest over 2 years ago in Developer Resources / Open Message Format (OMF) 2 No status

Write event when data source is offline

As a PI admin I would like the OPC UA connector to write a value such as 'disconnected' when the data source is offline so that I know when the connector is unable to connect to the data source,
Guest over 2 years ago in PI Connectors / PI Connector for OPC UA 3 Declined