To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 324

Support for Key Pair Authentication

Currently, PI ICU authentication relies on traditional username/password methods. However, this authentication approach is becoming increasingly obsolete and is not supported by many of the modern platforms and security frameworks we are required ...
Kareema Ramli 3 months ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 0 No status

Allow setting interpolation type in Adapters

We would like to be able to specify the interpolation type (linear vs step) when Adapter creates tags in Archive.
Damon Vinciguerra 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Interface for OPC AE Instrument tag any attibute should work

As now it is just Source and Area event attributes that work for the instrument tag. It should be possible for any attribute to work as a filter in instrument tag. It is not every OPC AE server that supports Source and Area.
Hobbe over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Support "Data Handling" options for adapters

The PI Interface for OPC DA can write IO timeout when it cannot get values from the OPC server. It would be useful to have the same option for the adapters so that stale data is marked IO timeout or similar, and automatically invalidates calculati...
Mike Horrocks 10 months ago in AVEVA™ Adapters / General 1 No status

PI BACNET interface support BACnet Intrinsic Reporting (BIR)

PI BACNET interface should support BACnet Intrinsic Reporting (BIR). It allows PI BACNET interface to subscribe alarm information. We will not miss the alarms if it will be implemented.
Kenji Hashimoto 4 months ago in PI Interfaces / Other Interfaces 0 No status

Design some UI for PI Adaptors

Design some UI for PI Adaptors, so it will be user friendly to configure the data source or data reading configurations etc. It is really hard to configure or troubleshoot an issue in PI Adaptor without Proper UI.
PradeepKumar Logandurai about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 1 No status

Support for the VT_UI4 data type

As a PI System User I would like to archive and analyse VT_UI4 data using the PI System.
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Support float64 point type in PI Interface for China Network Isolator

China Network Isolator interface does not support float64 point type, which is required by many customers in China. Right now, they have to change the point type to string first and then to float64 by analytics, this will consume two times of lice...
Guest over 3 years ago in PI Interfaces / Other Interfaces 3 No status

Configuration reconnection (retry) time on the adapter

OPC UA adapter takes 5min by default to reconnect to a load balanced PI Web API pair which failed over.
Guest 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Adapter to failover when there is egress issue

When connection to the datasource are all good for all the adapter failover members, but the primary adapter having issue connecting to the PI web API (egress) for example, adapter does not failover. Unlike PI Interface UNIINT failover, when there...
Ee Sheing Lee about 2 years ago in AVEVA™ Adapters / General 2 No status