Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

AVEVA™ Adapters

Showing 77

Support OPC UA ReverseConnect

Support ReverseConnect, allowing for the connection to be establish from the more secure area where the OPC Server reside to the least secure area where the OPC Client / Adapter resides. This is implemented in many other client tools and SDK such...
Gabriel Verreault over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

PI adapter for PI-to-PI

We need a new robust product to support data transfer between PI servers in separate domains (operational network --> business network). This product would need to support the following: Highly available remote management/deployment multiple in...
GaryYegiazaryan over 2 years ago in AVEVA™ Adapters / New Connectivity 3 No status

PI Adapter High Availability Resilience

Problem Summary: The client failover service for PI adapter is not highly available. If the client failover service node is unavailable, then the PI adapter instances that it manages will lose failover functionality. This is further exacerbated if...
GaryYegiazaryan over 2 years ago in AVEVA™ Adapters / General 1 No status

Support for the Galileosky Protocol

Need an option for direct integration of Galileosky GPS tracking devices with the AVEVA PI System without third-party middleware. The devices primarily use the proprietary Galileosky binary protocol (TCP-based, port 20332 by default) for real-time...
Mohammed Qasim Asghar 4 months ago in AVEVA™ Adapters / New Connectivity 0 No status

REST API data source

e.g.: weather forecast, 3rd party
Guest over 3 years ago in AVEVA™ Adapters / New Connectivity 0 No status

PI Adapter for Apache Kafka

Create a PI Adapter that supports reading data from Apache Kafka. Please comment with any specific data, requirements, or use cases that this adapter would need to support!
Ellery Murdock over 3 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Add the option "Ignore Bad_WaitingForInitialData Status"

In the connectors there was the option "Ignore Bad_WaitingForInitialData Status", as described here. For gen 1 there was a need to edit the config files directly, and in gen 2 the option was integrated into the UI. Instead for the adapter I recent...
sahilp over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Adapter for GE e-terrahabitat/HabConnect

We need a new robust product to support data transfer between GE e-terrahabitat/HabConnect and PI. This product would need to support the following: Highly available remote management/deployment multiple instances on a single node (to support larg...
GaryYegiazaryan over 2 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Support System States for the Adapter for Azure Event Hubs

The data passed through the Adapter for Azure Event Hubs can be very dynamic in its configuration. It would be useful to be able to send system states to indicate bad data, and possibly the nature of that bad data. In the same way that interfaces ...
Mike Horrocks about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 2 No status

PI Adapter for OPC UA should send the previous value when it has been with the same value for a long time

"This enhancement request proposes a solution to address the issue of data interpolation between two values far apart in time in adapter data collection. The suggestion is to include the value right before the new data point, ensuring the fidelity...
Fabio Dani almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status