Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 1675

Allow substitution parameters in attribute template description

As a user, I want to be able to use substitution parameters in attribute template descriptions, so that when elements are created from template, the attribute template description can be substituted with pertinent information. Note: This was prev...
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 7 No status

PI EF security trait/context

We are trying to standardize and mutualize all of our templates but we want to keep the security well defined : in general it work perfectly when things are in read only mode. Where write access is needed everything looks good for Elements since t...
dgenet 3 months ago in AVEVA™ PI Server / Event Frames (EF) 1 No status

Support import/export of AF tables in PI Builder

As a user, I want to be able to import/export AF tables using PI Builder, so that I can make changes as needed.
Guest over 3 years ago in AVEVA™ PI Server / PI Builder 5 No status

It would be great to have an option to backfill/recalculate Event Frame analysis without sending notificaiton.

I know, that notifications are not sent for event frames older than 72 hours, but that 3 days is still too long. Usually we just want to recalculate  Event Frames to have a proper statistic about the past in reports. The notification is use...
Guest over 3 years ago in AVEVA™ PI Server / Notifications 10 No status

Highlight attributes not matching template

PI System Explorer should visually highlight attributes of template based elements that have changes to the template.
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 13 No status

ICU startup on high latency networks

On high latency networks, it can take ICU many minutes to start because every interface on the PI Data Archive is checked. Minimize startup time by caching a node's registered interfaces.
Guest over 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 11 Future consideration

Trigger AF Analysis Using Future Data

As an engineer, I want to execute analyses when I get a new future data value, so that any forecasts (either via Analysis or via a 3rd party system or via a PI Point update) can trigger analyses.
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 12 No status

Track if auditing was turned off

I want the ability to track if auditing was turned off for the PI System (PI Data Archive and AF) so that I can determine if there was the risk of potential changes that were not captured by PI System audit functions.
Guest over 3 years ago in AVEVA™ PI Server / System Management 11 Evaluating

PI EMDVB Interface should not use the STARTUP.dat to determine recovery start time when configured in Failover and running in RealTime mode.

Currently when the PI Interface for Emerson DeltaV Batch (EMDVB) is configured for failover and running in RealTime mode, the interface will use a recovery start time (RST) based on the last time the interface was active. This results in the inter...
Bethany Jewett over 1 year ago in PI Interfaces / Batch Interfaces 2 Planned

Variable True For parameter for Event Frame Analyses

As an AF Administrator, I want to configure an Analysis Template for Event Frames with a True For parameter that would have it's value stored in an AF Attribute (configuration item). The use case is that elements built from the template will have ...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 3 No status