To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 3549

Ability to quickly add "Filter Expression" on adhoc

Will it be possible to improve the AdHoc capabilities to allow adding the "Filter Expression" instead of trying to create a calculated value in PI Vision and then dragging into a trend and finally saving the trend?
Kimlin Pen about 2 months ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 0 No status

Add Function to Determine if a Bit is Active in a Word Value

It would be extremely helpful if a function existed within PI AF where could provided a value/tag reference and a bit number to check and see if its active. The function would return a True or False value if that bit is active. Something like the ...
Justin Jackson about 2 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Compression on CONNECT to PI related tags

The tags use the default compression settings since they are automagically created through PI WebAPI if CONNECT to PI agent starts sending the transfer. This can mean that there is another compression applied to the tags. But as we are already cop...
Hans-Otto Weinhold 11 months ago in CONNECT to PI 0 No status

Support "Data Handling" options for adapters

The PI Interface for OPC DA can write IO timeout when it cannot get values from the OPC server. It would be useful to have the same option for the adapters so that stale data is marked IO timeout or similar, and automatically invalidates calculati...
Mike Horrocks 11 months ago in AVEVA™ Adapters / General 1 No status

Option to remove/edit template prefix

Allow for connectors to create templates without the fixed prefix. E.g. The option to name an AF template "templatename" and not "UFL.templatename"
Guest over 3 years ago in PI Connectors / General 0 No status

Add point Type INT64, UINT64, to PI Archive

Some interfaces such as PI Modbus allow the polling of a 64-bit signed integer value or a 64-bit unsigned integer value. Yet the database does not allow you to store these values in their native formats. You must store them as a 64-bit floating po...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 4 No status

Allow default value for rollup analysis

Allow a default value to be specified for rollup analysis. This value would be used when the rollup cannot find any matching attributes, thereby eliminating a lot of rollup analysis errors and Calc Failed values from being written.
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 7 No status

Enhance functionality of NumOfChanges

By now the NumOfChanges Function in AF Analytics does not take into account the value at the start of the timerange. NumOfChanges only counts the amount of changed values of the recorded values in the given timeframe. If I query the NumOfChanges ...
Jürgen Schmidt over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 4 No status

Date Format in AF Event Notification

In AF please provide a way to suppress time zone and/or to format the timestamp in AF Events, particularity, Notifications. For example, in the message format in e-mail notification I do not need to indicate the time zone it was triggered in. Ple...
Guest over 3 years ago in AVEVA™ PI Server / Notifications 3 No status

It would be great to have the ability to hide the Event Frame End Time in the Notification Email When a Notification Triggers

It would be great to have the ability to hide the Event Frame End Time in the Notification Email when the notification first triggers. At this time, and End Time of 12/31/9999 11:59:59 PM Central Standard Time (GMT-06:00:00) is displayed even thou...
Guest over 3 years ago in AVEVA™ PI Server / Notifications 3 No status