Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 4912

Enable OmfEgress component to be configurable by instance (by component)

In our process we wish to send a different set of data to different PI environments. For instance we would like all data to egress to the PROD environment while only egress a subset of data to the DEV environment, in which we don't need all the da...
Guest over 2 years ago in AVEVA™ Adapters / General 2 Future consideration

PI Data via MQTT Broker

Allow external applications to consume PI system data via MQTT.
Guest about 2 years ago in AVEVA™ PI System Access (PSA) / General 2 No status

Expose methods to retrieve messages from the PI Message log to PI AF SDK

Add methods to retrieve messages from the local and remote PI Message Logs where remote can refer a PI Data Archive node or any remote PINS. Because the EventLog Class in .NET Framework provides access to local and remote Event Logs, offering th...
Guest about 2 years ago in AVEVA™ PI System Access (PSA) / PI AF SDK 3 Declined

Allow sending data to the OPC UA Server

Currently the Interface is supporting read only. Sending data is also required
meierke1 about 2 years ago in PI Connectors / PI Connector for OPC UA 3 Declined

PI OPC UA Connector - point attribute based configuration

We are just starting the first tests with PI OPC UA Interface. We notice that the classic method of tag configuration, known from the interface, is no longer possible. This is probably due to the connector concept. Unfortunately, this does not fit...
Guest about 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

PI Auditviewer Usability Enhancements

From a pharma/biotech user perspective, I am finding that the PI Auditviewer application is difficult to use and conduct an investigation with over an extended time period.  I believe the application needs an overhaul to allow for, at minimum...
Guest about 2 years ago in AVEVA™ PI Server / General 1 No status

Set name of Event Frame on close (or by the value of an EF output attribute)

It would be useful if Analysis Service would set the name of the Event Frame on close rather than open. The use case is customer wants to dynamically set the name by a value of an EF attribute (possibly an EF output attribute) - for example, if a...
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 4 No status

Stop EF after given time

Als a PI admin I want to have the option to stop/end a EF after a given time. This helps to trigger and track onetime events as for example taking a reactor sample.
meierke1 about 2 years ago in AVEVA™ PI Server / Event Frames (EF) 3 No status

Add additional Analysis Search Criteria options to PSE Management

It would be helpful if you could search by Element Category or Element Description when searching for Analyses in PSE. My setup is 5 templates (CHW, Water, HW, Electric, Steam), each of which have accounts that can come from 5 different sources (s...
Kelsey Bobeck about 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 2 No status

As an avid user/admin of AF, in PSE I would like an option to display large attribute values with commas

Currently, in PSE there is no way to display attribute values greater than or equal to 1000 with commas for the thousands separators. Ex: 1,234,456 instead of 123456. This option exists in other PI Clients (i.e. PI Vision) and should be available ...
Guest about 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 Declined