Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 5288

PI to Maximo integration

When PI is used to gather equipment sensor information but Maximo is used for asset management, it would be helpful to have a simple way to get equipment information out of PI and into Maximo.  This would be useful for scheduling preventative...
Guest over 3 years ago in PI Integrators / General 4 No status

Support transfer of assets and events from CONNECT to PI AF

Support transfer of assets and events from CONNECT to PI AF. This is essential to provide proper data sharing between PI Systems through Community data sharing of CONNECT (PI CloudConnect Equivalent) but also if data is available in CONNECT (e.g.,...
Hans-Otto Weinhold about 2 months ago in CONNECT to PI 0 No status

resume ad hoc trend, without having to add a new tag

in previous pi-vision version, you were able to go back to the ad hoc trend you made earlier. now you can only do this by adding another (unwanted) tag first, which you have to remove then
Guest about 2 months ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 1 Already exists

Allow configurable PI Point Lookup priority whether to use PI Point name or PI Point ID first

Currently, in PI Vision display, PI Points data items are stored using both the PI Point ID and PI Point Name. During data retrieval, PI Vision prioritizes resolution via PI Point ID and only falls back to PI Point Name if the PI Point ID is not f...
Mohammed Al-Shaikh 6 months ago in AVEVA™ PI Vision™ / Administration 0 No status

Dump all tags from a point source, select all, display point values with timestamp

In PI ProcessBook, when defining a trend, you could perform a tag search dumping all tags tied to a particular point source, and then select all tags and get the point values and timestamp of last update and scroll through the entire list. This is...
Chris Swiecicki 9 months ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 0 No status

Give the ability upload different Tag Naming files in DCM / OPC UA Connector

When uploading a "Tag Naming" file in DCM, this file completly replace the existing Tag naming. It mean that a Tag naming file must be done for all datasources within one connector. It would be a lot more easy when dealing with a large number of t...
Fred_EYRAUD over 3 years ago in PI Connectors / PI Connector for OPC UA 2 No status

PI Connector Relay support write modes

While writing data to PI through the connector relay there seems to be no option to control the write mode . E.g."[-109] Value at This Time Already Exists" is shown in the logs if the archive already contains an event with the same timestamp. The ...
Guest over 3 years ago in PI Connectors / General 2 No status

PI Auditviewer Usability Enhancements

From a pharma/biotech user perspective, I am finding that the PI Auditviewer application is difficult to use and conduct an investigation with over an extended time period.  I believe the application needs an overhaul to allow for, at minimum...
Guest over 3 years ago in AVEVA™ PI Server / General 1 No status

Set name of Event Frame on close (or by the value of an EF output attribute)

It would be useful if Analysis Service would set the name of the Event Frame on close rather than open. The use case is customer wants to dynamically set the name by a value of an EF attribute (possibly an EF output attribute) - for example, if a...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 4 No status

multiple instances of analysis service

As a PI administrator I would like to be able to create multiple instances of "PI Analysis Service" windows service for these reasons: - avoid new potentially problematic analysis from affecting the ones that are operational and working correctly ...
Phillip Riesinger over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 6 No status