Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 3576

Allow different permission models and "view effective permissions for user" features within tenant

For sharing data to external clients who are not PI/CONNECT users, we cannot use the community sharing and permissions model and instead have to add users to an org's tenant. By default, all users are granted the tenant member and tenant viewer ro...
Adam Bolin about 2 months ago in PI to CONNECT / General 0 No status

Ability to add optional elements in an asset view's shape

Currently when building an asset view's shape, the matches received would only cover the elements that are found in the PI AF database that match that shape. It would be good to have an option where if a child element is considered optional in the...
Guest over 1 year ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Calculated tags present value error

For calculated tags when being trended for more than ~12 hours time frame, the trend works fine except for the live present value, the calculation can be completely off. See attached screenshot for an example, where several tags are checked whethe...
AbdulRahman.Maskari 4 months ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Limit Analytics to Only Write to Specific Pointsource

A useful setting for PI Analytics would be the ability to specify a specific pointsource that the Analytic service writes to. This would help tremendously to troubleshoot what tags on the PI DA server are being written to by AF Analytics.
Brian Rock over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Generic access to Customer Portal until user added to site

We need the ability for a user to gain generic access to the Customer Portal until they are added to a specific site. We have users who create an SSO themselves but can't submit a case until they get added to a site (generic No Access received). ...
bhilgemann over 3 years ago in Customer Portal & PI Square / Customer Portal Overall 1 No status

OPC UA Connector Trend Advise Option

OPC UA Connector Trend Advise Option, such as in the UniInt interfaces
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 5 No status

Have option to enable exception on Connectors.

There are use cases where data is sent over networks with latency (satellite link, for example) so being able to filter out noise at the connector is important.  This is also important when a connector sends data to a local PI Server in the f...
Brent Bregenzer over 3 years ago in PI Connectors / General 5 No status

Enable Relay/DCM to allow control over the data streams and destination PI Systems

Currently the Relay will send all data streams to all routed destination. This does not allow customers to have control over what data streams go to a specific destination. The only workaround is to have independent Connector/Relay pairs with spec...
Nico Cha over 3 years ago in PI Connectors / General 1 No status

Provide more granular configuration for default ACLs

As a PI Administrator of a PI System with complex security requirements, I need to set up different default permissions for various users so they can create tags that automatically have the proper security instead of having to rely on a process/pr...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 2 No status

Allow BadVal to check multiple inputs or IFERROR

Right now BadVal can only check one variable or Expression.  So if I am evaluating an expression with say 10 inputs, and I want the expression to output NoOutput() if any one of the 10 inputs are BadVal, then I have 2 options right now. ...
taterhead247 over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 5 No status