To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Interfaces

Showing 302 of 4765

For PItoPI interface having a source PI-HA server, allow failover on source without using PI interface status utility.

For PItoPI interface having a source PI-HA server, allow failover on source without using PI interface status utility. This should allow failover based on connectivity and/or a watchdog (like failover if a specific tag stay stale for a configurabl...
Guest over 1 year ago in PI Interfaces / PI to PI Interface 0 No Status

Allow the UFL interface to delete PI tag data or provide some other supported automated method of deleting PI data from a collective.

There is no way to easily delete data in a time range if you want the changes to occur on both the primary and secondary data archive. It seems the UFL interface would be good to use to do this. You could provide it a tag name and time range and t...
Heather Boehler over 1 year ago in PI Interfaces / PI Interface for UFL 3 No Status

PI OPCtoCSV Tool: Filter by OPC ItemID

The PI Interface for OPC DA is packaged with the PI OPCtoCSV tool which extracts all OPC Items. It is possible to filter the items by subbranch like the PI APS Connector for OPC DA interface, but unlike the APS Connector, it is not possible to fil...
Guest over 1 year ago in PI Interfaces / PI Interface for OPC DA 0 No Status

Output at close option on EFGen

It would be interesting to have an 'Output at close' option on EFGen like we have on a normal Event Frame Generation.
Carlos Castro 2 months ago in PI Interfaces / Other Interfaces 0 No Status

PI BACnet interface: add support for BACnet Setpoint object

Add support for BACnet Setpoint objects in the PI BACnet interface.
Kenneth Reiss over 1 year ago in PI Interfaces / Other Interfaces 1 No Status

Support multiple Modbus devices on the same machine

Add support for multiple Modbus devices (using the same IP address but different port numbers) on the same machine. For example, the interface could allow the user to configure something like this: /dn= xxx.xx.xxx.xx:43120,/cn=1,/polldelay=0,/to...
Guest over 1 year ago in PI Interfaces / PI Interfaces for Modbus 3 Declined

Log bad timestamps for the PI RDBMS Interface

When the PI RDBMS Interface gets a bad timestamp from the source RDB that it cannot coerce into a PI Timestamp, the actual bad timestamp received from the RDB should be logged as part of the error message. This would coincide with the following e...
Guest over 1 year ago in PI Interfaces / PI Interface for RDBMS 0 Future Consideration

and operator

Add a function that can be used in the UFL Configuration File to perform bitwise operations. For example, a function similar to the AND operator in Performance Equations and Asset Analytics.
Guest over 1 year ago in PI Interfaces / PI Interface for UFL 1 Declined

PI OPCtoCSV tool to continue running and skip branches in error

The PI Interface for OPC DA is packaged with the PI OPCtoCSV tool which extracts all OPC Items. When the tool is run into error with certain branches, the tool will stop and disconnected from the OPC server/tunneller. For example: “GetItemProperti...
Ee Sheing Lee over 1 year ago in PI Interfaces / General 1 Declined

PI Interface for IEEE C37.118 support for Analog data Signed and Unsigned 16-bit Integers

The IEEE specification of the IEEE C37.118 protocol does not specify if analog data should be singed or unsigned for 16-bit integers. The currently the PI Interface for IEEE C37.118 represents these values as exclusively unsigned. Both types shoul...