To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

PI SQL Client to make use of the RecordedValue method and Retrieval Modes for the GetValue transposed function

When making use of the GetValue transposed function when creating a new Template specific Data Model, we can see that under the hood it makes us of the AF SDK call AFData.InterpolatedValue method to capture the data at a specified timestamp provid...
Guest about 4 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 1 No status

Enable Multiple PI to CONNECT agents for one PI Data Archive

Aside from our main AF Server setup used for numerous use cases like energy, OEE, etc, we have created a second environment of AF Server / AF Analysis / SQL Server to isolate the monitoring of a critical process. We are still making use of a singl...
Christian Leroux over 3 years ago in PI to CONNECT / General 0 No status

Provide option to re-use or not re-use OIDC access tokens when connecting to multiple AF systems using PI System Explorer

At the moment, PI System Explorer defaults to re-using OIDC access tokens when connecting between AF systems. For customer systems where there are multiple independent AIM servers for different AF systems (potentially because of different countrie...
Tze-Wei Lim 7 months ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

21 CFR Part 11 Electronic Signatures for manual data entry

Support 21 CFR Part 11 regulatory requirements for Electronic Signatures when manually entering data.
Guest about 4 years ago in AVEVA™ PI Vision™ / Manual Data Entry 2 No status

Connector should rescan UA server, on a configureable basis, for new objects already defined in CSV file

It would be helpful if the UA Connector could rescan the UA server for new objects that have already been selected in the AvailableTypeDefinitions file and add them to the server on a configurable frequency.  We primarily use the UA Connector...
Steve Hampton about 4 years ago in PI Connectors / PI Connector for OPC UA 2 No status

Ability to monitor which OPC UA Connector is active in a failover pair

As a PI administrator, I need to monitor which OPC UA Connector in a failover pair is currently active. When the primary OPC UA Connector goes down, I need an email notification, and vice versa when the secondary OPC UA Connector goes down.
Guest about 4 years ago in PI Connectors / PI Connector for OPC UA 2 No status

Extend PI audit trail to include changes made to snapshot using SMT

Using the SMT tool with the PI archive editor you can enter current values using * as time. This enters directly into the snapshot but is not recorded in the audit trail. All changes made should be recorded
Carl Van Laer about 4 years ago in AVEVA™ PI Server / General 0 No status

Delay Real-Time Calculations until backfill is finished.

For recursive Analyses such as below : PrevVal(tagA,'*') + 'TagB' → output : tagA When the PI Analysis Service is down (or the node needs to be restarted), the current calculation needs to be halted until the Backfilling reaches up to the start u...
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 3 No status

Event Frames Scalability

Ability to scale event frames to support hundreds of millions of EFs per year.
Guest about 4 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Specify stream properties in a CONNECT to PI transfer

Include a way to select (or filter out) different properties of a stream used in a CONNECT to PI transfer so that we can control the PI tag/s created.
Guest over 1 year ago in CONNECT to PI 0 No status