Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 4928

PI SQL Client to make use of the RecordedValue method and Retrieval Modes for the GetValue transposed function

When making use of the GetValue transposed function when creating a new Template specific Data Model, we can see that under the hood it makes us of the AF SDK call AFData.InterpolatedValue method to capture the data at a specified timestamp provid...
Guest over 2 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 1 No status

Expose PI Network Manager Statistics via AF SDK

As of now, we can get PINetMgr statistics via PowerShell command Get-PIConnectionStatistics. # of users familiar with AF SDK are more than with PowerShell. It will be nice feature addition in AF SDK, and usability will also increased.
Guest over 2 years ago in AVEVA™ PI System Access (PSA) / PI AF SDK 0 Declined

PI DataLink on MS 365

It will be great to have PI DataLink Add-on works on Microsoft 365 or allowing PI DataLink reports to be hosted in PI Vision.
Husain Al-Shaikh 4 months ago in AVEVA™ PI DataLink™ / Programming 0 No status

Allow options to alter the way the connector handles different qualities (bad, questionable)

At this time, the connector does not expose any way to alter the way data of different qualities (bad, good, questionable) is handled. The PI OPC Interface allows several different options with regards to “quality” such as "send only GOOD quality ...
Gabriel Verreault over 2 years ago in PI Connectors / PI Connector for OPC UA 1 Declined

Enable Relay/DCM to allow control over the data streams and destination PI Systems

Currently the Relay will send all data streams to all routed destination. This does not allow customers to have control over what data streams go to a specific destination. The only workaround is to have independent Connector/Relay pairs with spec...
Nico Cha over 2 years ago in PI Connectors / General 1 No status

Add point Type INT64, UINT64, to PI Archive

Some interfaces such as PI Modbus allow the polling of a 64-bit signed integer value or a 64-bit unsigned integer value. Yet the database does not allow you to store these values in their native formats. You must store them as a 64-bit floating po...
Guest over 2 years ago in AVEVA™ PI Server / Data Archive 4 No status

Show Child Attribute in Analysis PE Editor Auto-Complete

As a user configuring Analyses, I would the the Performance Equation (PE) Editor's auto-complete to suggest any child attributes as well as regular attributes.  Note: This was previously Enhancement 109589.
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 2 Declined

Date Format in AF Event Notification

In AF please provide a way to suppress time zone and/or to format the timestamp in AF Events, particularity, Notifications. For example, in the message format in e-mail notification I do not need to indicate the time zone it was triggered in. Ple...
Guest over 2 years ago in AVEVA™ PI Server / Notifications 3 No status

Send notification to additional persons based on change in severity

A way to configure a notification rule to send to additional contacts when the severity status changes without creating a new analysis. Customer use case: Customer wants to scan devices. If a device fails to respond (I/O Timeout) over a short per...
Guest over 2 years ago in AVEVA™ PI Server / Notifications 0 No status

Filter Expressions for PI Point Data Refences

Allow the use of filter expressions, similarly PI DataLink Compressed Data, so that you can visualize or perform calculations on filtered data (e.g., excluding bad values, certain digital states, etc.).
Guest over 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 2 Declined