Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

AVEVA™ PI Server

Admin Option to block check-in of linking an Analysis output to a Static Attribute

It is easy for AF Users to create a new attribute with Data Reference = None (aka Static Attribute) but then assign an analysis to update its value later. When this happens, all updates to the attribute are stored in table FindChanges_AT which can...
John Alessio 8 months ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Convert PI Builder from a COM add-in to an Office Add-in

This change will bring a few benefits: PI Builder will become more secure. COM add-ins use ActiveX, and ActiveX is both deprecated and not secure. PI Builder will become cross-platform. AVEVA will be able to publish PI Builder to the Microso...
Kenneth Barber 3 months ago in AVEVA™ PI Server / PI Builder 0 No status

Add configurable defaults for PI Point "Pointsecurity" and "Datasecurity"

Read access to the PIPOINT table is required for most identities. Pointsecurity and Datasecurity currently use the settings on the PIPOINT table as the default. New points will generally give read access to most identities because of these default...
Guest about 4 years ago in AVEVA™ PI Server / Security 3 No status

Improve Data Cache Performance by parallelizing Data Archive update fetches

Currently, when the Data Cache is signed up for updates on multiple data archives, updates from each archive are fetched in series, one after another. When there are many data archives involved (especially if they are geographically dispersed) thi...
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

Percentile function

As a user of analyses, I would like to have a Percentile function so that I can filter out atypical events when doing summary calls. The function would look like this: Percentile('attribute', 'timerange', value). This is related to enhancement req...
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 4 No status

Introduce compatibility between PCS AIM and Azure national cloud deployments

Currently, Platform Common Services (PCS) for the PI System is incompatible with Azure national cloud deployments (e.g. A U.S. government Entra ID instance) due to limitations with Microsoft Graph global service, upon which PCS AVEVA Identity Mana...
Ryan Biggins 9 months ago in AVEVA™ PI Server / Security 0 No status

Allow writing arrays as a time series to an output

I would like to be able to configure outputs in an analysis to write at multiple time points (which are defined by the result of an array function). My use case is to: 1. Configure an attribute as a Time Series Table Lookup 2. Create an analysi...
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 3 Tell us more

Enable Source Units Selection for Attribute in a PI Point Data Reference

When pointing at an existing attribute for a PI Point data reference it is not possible to select the Source Units. For example, if the Attribute being pointed to is the tag name which can be used as an input substitution parameter then the source...
Mohammed Qasim Asghar 28 days ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Enlarge area for editing analysis expressions

When editing an Analysis Expression, only 4.5 lines appear. It would helpful if more lines appeared (greater than 20 lines).
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 5 No status

PI System Management Tools SNMP Plug-in Initial Request to SNMP Devices

When using the PI System Management Tools SNMP Plug-in to create an Agent attempting to validate the agent configuration fails due to PI SMT sending the username specified in the SNMPv3 tab instead of sending <MISSING> or initial in the user...
Logan Fritz about 2 months ago in AVEVA™ PI Server / System Management 0 No status