Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 1742 of 5194

Add Event IDs to event logging

Currently, events logged for the OPC UA Connector all have an Event ID of 0. I've had to dig around in Event Viewer quite a bit for troubleshooting, and it's frustrating not to be able to filter events by ID. I mention the UA Connector because tha...
Guest over 2 years ago in PI Connectors / General 0 No status

Access to "HE" identifier-type historical data in OPCUA servers

Being able to retrieve "HE" identifier-type historical data from OPC UA server s if they are indeed presenter there/. This type of data is important as it provides historical alarms and events which were captured on the source OPC UA server
Guest about 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Dynamic EF root cause duration

To avoid creating several templates, suggested adding the possibility to choose the duration In the Event Frame-->Advanced Event Frame Settings-->Generate child root cause event frame before parent event frame starts, to be different for eac...
Gilbert Nassif about 3 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Create a utility to reprocess corrupted buffer files

It would be very useful to have a utility same as there is for PI buffer Subsystem files for connector buffered files It is common to get corrupted buffer files and we depend exclusively on tech suppport to get that data availabe
asanzacedo over 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Enable setting tag attributes in the PI Connector for OPC UA (gen1 and gen2)

The PI Connector for OPC UA (gen1 and gen2) should have ways to set tag attributes. There should be way to automatically set the PI point attributes like point and data security.
Paul Kim about 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Increase PI Notifications methods to include SMS text methods for AD users

Many notifications users are able to access notifications through e-mail, but due to the frequency or lack of importance to the platform they can be easily ignored. This proposal is to allow notifications to be sent to Cell Phones directly through...
Nathan Skitt over 2 years ago in AVEVA™ PI Server / Notifications 1 No status

Publish performance metrics

Performance metrics for the PI Server should be published with each release of the product.
Guest over 3 years ago in AVEVA™ PI Server / Help / Documentation / Videos 0 No status

Auditviewer separation of roles

I want to separate the security roles between 1) the ability to run an Auditviewer report and (potentially) associate a change control record to a configuration change and 2) the PI Admin Role in order to minimize security risk.
Guest over 3 years ago in AVEVA™ PI Server / Security 1 No status

Be able to configure PI AF security in a single PI System Explorer window

Currently, there are 2 windows to configure PI AF security, and it is a pain to switch between them: File → Database → Edit Security, which is used to assign permissions to identities File → Server Properties → Identities tab and Mappings tab, whi...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / Security 1 Declined

Have a consistent presence of a terminating \ in the PIHOME and PIHOME64 environment variables

By default, PIHOME is "C:\Program Files (x86)\PIPC" and PIHOME64 is "C:\Program Files\PIPC\". For new installations, please consider either having the terminating \ on both or removing the terminating \ from both. The current inconsistency can con...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / Installation 0 No status