To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

PI Adapter for OPC UA data conversion

As a PI System Administrator, I would like to be able to apply conversion factors to the data that is being gathered from our OPC UA server. This would allow us to get data in the format/units we'd like, without requiring extra tags and/or calcula...
Guest about 4 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status

Allow configuration of Trend legend position

As an report designer, I would like to be able to choose the position of the legend on Trends.
Guest about 4 years ago in AVEVA™ RtReports 0 No status

OPC UA server failover based on watchdog tag

Gen2 PI Connector for OPC UA support OPC UA server level failover. How the Connector determine when to failover to the other OPC UA server: As per 6.6.2.4.2 ServiceLevel , this is used by the client to determine whether to connect/disconnect fro...
Ee Sheing Lee 10 months ago in PI Connectors / PI Connector for OPC UA 1 No status

Show Target Indicator on Gauges

It is a very quick way to show if a value is currently above or below a target if an indicator can be included on a gauge. For example, on the vertical gauge to have a triangle pointer to left/right/both side of the gauge, or a line across the gau...
Mike Horrocks 10 months ago in AVEVA™ PI Vision™ / Symbols 0 No status

processor rate(s) for Processor properties of Modbus Adapter Service Health

Visualize and understand usage when trended with other diagnostic properties.
Guest 3 months ago in AVEVA™ Adapters / General 1 No status

OMF Egress health to include stream count

Validate stream count for scenarios where there are multiple Components
Guest 3 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Store an OPC Server's "VT_EMPTY" Data Type as a "Bad" in PI Data Archive

When there is a problem within an OPC Server, some Items receives "VT_EMPTY" data type values. PI OPC DA Interface ignores this information, and in PI Data Archive present to users and applications the last valid value - that might be incorrect.
jmalmeida over 1 year ago in PI Interfaces / PI Interface for OPC DA 0 No status

Ad Hoc - Ctrl + click for multiselect trends to be highlighted

When investigating an issue, I often work with 10 or more attributes in an Ad Hoc display. The highlight function is helpful, but because it dims all other trends, it reduces overall comparability. While I can manually toggle values on or off, or ...
Oerjan Sikveland about 1 year ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 0 No status

Scale Grouping Window Needs Scrolling

With Long tag names when you select items to group 1 then the window pans to the right and you can't add additional tags to a group 2. If the window had a horizontal scroll or ability to resize you could scroll to the left side to add additional tags
Guest 3 months ago in AVEVA™ PI Vision™ / Display Management / Displays Page 0 No status

Ability to search and add a PI point directly on an ad hoc trend workspace.

Ability to search and add a PI point directly on an ad hoc trend workspace. I have added an sample of the ad hoc trend workspace
Guest about 1 year ago in AVEVA™ PI Vision™ / User Experience 0 No status