To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 86

Have both default PI Data Archive and Asset Framework Server load in generator

Some customers are using the same RtReports Server to connect to both PI Data Archives (for batches) and Asset Framework Servers (for Event Frames) since they are using both at the same time. They'd like to be able to store both DA and AF/Database...
Alan Izar over 3 years ago in AVEVA™ RtReports 1 No status

Better support of IP21 OPC UA Server with PI Adapter for OPC UA

We have been using the PI Adapter for OPC UA in its current version to collect data from IP21 OPC UA Server during a lighthouse project. However, the configuration was a bit cumbersome since the OPC UA Server of AspenTech uses an opaque mechanism ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Make a BACnet/SC adapter

BACnet/SC is essentially the same as BACnet/IP... but secures the communication
Nate Anderson over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 1 No status

AVEVA Adapter for WITSML

We need an Adapter for WITSML to get data from drilling, completions, and interventions of oil wells to CONNECT data services, so the data can be shared between multiple stakeholders.
Guest over 1 year ago in AVEVA™ Adapters / New Connectivity 0 No status

CONNECT Agent for AVEVA Plant SCADA (Citect)

AVEVA Plant SCADA 2020r2 and newer, has an OPC UA Server, so the AVEVA Adaptor for OPC UA can be used to send data to CONNECT data services (AVEVA Data Hub). However native connectivity like the PI-to-CONNECT Agent or the System Platform Connector...
Guest over 1 year ago in AVEVA™ Adapters / New Connectivity 0 No status

Parse String Tag Using an AF Attribute as a Filter

Following the "Parse String Tag Using an AF Attribute as a Filter" KCS is a very complex setup to filter Strings based on AF Attribute values. We would like to see the filter functionality enhanced to allow filtering based on an AF Attribute Valu...
Guest over 3 years ago in AVEVA™ RtReports 0 No status

Including the name of the report parameter used in the print-out PDF's file name

It would be much easier to browse the output print-out PDF files from the RTreports generator if the file's name includes the report paramater under which the report was generated. At the time being, the report only includes a unique GUID for each...
Guest over 3 years ago in AVEVA™ RtReports 0 No status

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Nico Cha almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status