Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

AVEVA™ PI Server

Showing 1344 of 5209

Expose the ExDesc of a PI Point on an AF Attribute.

Expose the ExDesc of a PI Point on an AF Attribute. This would permit to retrieve additional metadata from PI Points that can be used in AF.
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

Add the ability to display UOMs in different languages in the PI AF Client

Automatically display UOMs in the PI AF client in the language of your choice i.e. not a conversion of units. For example, to change the display of UOMs to Russian instead of English, kg becomes кг, V becomes B.
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Use different Windows account for linked table authentication

As a user, I want to have the option of entering a service account's Windows credentials when authenticating to a Table Connection in PI System Explorer. Currently, the Windows authentication mode only allows impersonation of the user running PI S...
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Validating AF Servers Match

As a PI Admin in a highly regulated environment, I need to demonstrate that the AF Servers in my production and qualification environments are identical. OSIsoft does not recommend comparing PIFD databases directly, and there are small difference...
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Create substitution parameter for parent of referenced element

I would like to be able to reference the parent of a element reference. As it currently stands, it is only possible to reference the original parent element of an element.
Roger Ward over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

Supporting Decimal type for PI tag in PI Data Archive

For customers from special fields (eg: Pharma industry ), they would like the value to be accessed as exactly 16.168 , and would like to know if data type " Decimal " can be introduced for PI tags in PI Data Archive; Just like the following descri...
Peng Li about 2 years ago in AVEVA™ PI Server / Data Archive 0 No status

Add Continue() Function To Asset Analytics

Similar to the Exit() function, a Continue() function would be very helpful in reducing the calculation load on my analysis service, in this case by not fully executing variables if a condition is true. For example, if I'm evaluating the state of ...
Kelsey Bobeck over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Add the option to set the Event Frame output to be the value of a string attribute with the longest time-span over the Event Frame Duration.

I have an Event Frame string attribute that changes its value over the duration of the Event Frame. I'd like to have the option to set the Event Frame output to be the value of the string attribute with the longest time-span over the Event Frame D...
Dave Tayler about 1 year ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Tool to check if a PI Point is used in PI AF Analysis

I would like to suggest a tool (a native function or utility) to check whether there are calculations in PI AF that reference PI points. I should notice that is even for the situation that I don't know whether this PI point is an input or output o...
Gustavo Martins about 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Remove Microsoft Visual Studio 2010 Tools For Office Runtime (VSTO Runtime) from any install kits that contain PI AF Client

According to this, VSTO Runtime is included with PI AF Client for the sake of PI Builder. The installation of VSTO Runtime also causes the 32-bit and 64-bit versions of the Visual C++ 2010 Redistributable to be installed as well. However, accordin...
Kenneth Barber over 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 Declined