To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 4912

Redundancy for PI Connector Relay

Operating in a validated pharmaceutical industry, when making use of a comprehensive data/asset centralizing approach, we require the PI Connector Relay to be redundant or highly available. We are currently in the obligation to deploy the PI Conne...
Christian Leroux almost 2 years ago in PI Connectors / Other specific PI Connector 0 No status

Enable Adapter for OPC UA to use the Pub/Sub method

Pub/Sub is proposed to be a more efficient and scalable method of transferring data using OPC UA. Allowing the adapter to access data in this way would increase the options for data collection, and allow the OPC UA adapter to be used in many more ...
Mike Horrocks 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Connector level failover - PI System Connector

Support connector-level failover in PI System Connector. Similar to UniInt failover (interfaces). Failover options should support hot, warm and cold failover.
GaryYegiazaryan 8 months ago in PI Connectors / PI System Connector 1 No status

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status

Allow PI Collective members to be permanently represented by alias names

For example, in PI SDK, when viewing "member setup" for a PI Collective, it is desired for the names of the members to always be represented as a DNS alias or SDK alias. At the outset of PI Collective creation, in PI Collective Manager for instanc...
Ryan Biggins 4 months ago in AVEVA™ PI Server / System Management 0 No status

CSV-002 valve position does not reflect actual plant status

PI Vision page 442 for Containment Spray CSV-002 does not match what actual plant status in for All 4 Units. All 4 Units have the valve OPEN but it shows CLOSED.
Guest 4 months ago in AVEVA™ PI Vision™ / Display Management / Displays Page 0 No status

Enable Dynamic Transfer Selection Criteria that PItoDH periodically re-evaluates

Have an option such that the transfer selection criteria are dynamically evaluated. Example: User selects AF root node Chooses "all elements" below that node Rather than explicit selection of add elements, evaluate dynamically so that as elements ...
Brian Deslatte 6 months ago in PI to CONNECT / General 0 No status

Improved sending of data from pi integrator to kafka

It is proposed to improve performance in sending data to the destination kafka. The backfilling and update data have been greatly delayed with respect to the previous version to 2020 R2 P1, which sends 30 messages per second, and the previous 7000...
SheilaG almost 2 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

RDBMS Interface version that support the failovertime > 20s (UFO_Interval)

If you have a query that lasts longer than 40s and a phase2 failover configuration is used. The interfaces switch constantly from primary to secondary and viceversa. With the parameter "UFO interval" you can control this behavior. However, this pa...
MiguelPalomo about 2 years ago in PI Interfaces / PI Interface for RDBMS 1 Declined

Correct pointDB_RemoveEmptySource behaviour or change Point Source Management

Hello, About the tuning parameter pointDB_RemoveEmptySource the following Article : https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=KB01008 Indicates : Perform any of the following actions to trigger removal of empty point sou...