To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 4931

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
sahilp over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

PI Vision Export to CSV - Needs all Tags that show up on the Display

PI Vision does not allow exporting of all of the tags seen on the PI Vision display, when using the export to csv. It only exports the tag if a value is timestamped within the range of start/end time filters. This is deceiving because on dashboard...
Dan.Louchbaum 12 months ago in AVEVA™ PI Vision™ / Reporting 0 No status

Redundancy for PI Connector Relay

Operating in a validated pharmaceutical industry, when making use of a comprehensive data/asset centralizing approach, we require the PI Connector Relay to be redundant or highly available. We are currently in the obligation to deploy the PI Conne...
Christian Leroux about 2 years ago in PI Connectors / Other specific PI Connector 0 No status

Improved sending of data from pi integrator to kafka

It is proposed to improve performance in sending data to the destination kafka. The backfilling and update data have been greatly delayed with respect to the previous version to 2020 R2 P1, which sends 30 messages per second, and the previous 7000...
SheilaG about 2 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Add functionality to PI Vision migration tool to auto convert buttons to links

Hello, PI Vision no longer supports buttons, but rather uses links, meaning that after migration, all buttons cease to function. Currently the only option available seems to be manually converting all buttons to links post migration. Is adding an ...
esb_support 10 months ago in AVEVA™ PI Vision™ / ProcessBook Migration 0 No status

RDBMS Interface version that support the failovertime > 20s (UFO_Interval)

If you have a query that lasts longer than 40s and a phase2 failover configuration is used. The interfaces switch constantly from primary to secondary and viceversa. With the parameter "UFO interval" you can control this behavior. However, this pa...
MiguelPalomo about 2 years ago in PI Interfaces / PI Interface for RDBMS 1 Declined

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status

BACnet Trend Log Object Collection.

BACnet TrendLog is an object that a controller may implement. Once configured, it’ll keep in memory a certain number of records for one particular point. It functions as a buffer in BACnet controllers to hold historical data in the event of discon...
Guest 4 months ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

PI Agent backfill historical value changes

If PI to CONNECT agent goes down, when it comes back online it should be able to capture any changes made in the data history (beyond just backfilling the data between the time it went down and when it came back online).
Max Mckay 4 months ago in PI to CONNECT / General 0 No status

Allow NaN value or NULL

.TCurrently, when sending PI data to CONNECT data services, if an atribute has NaN as value, the whole asset is removed from the transfer. Would like to support NaN or have NULL values in CONNEC