To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Interfaces

Showing 314

Create 'Close Event Frame delay' setting

When you create PI Point Data Reference attributes in event frame templates that are used by PI Batch Interfaces, the PI Batch Interface will be responsible for resolving and capturing this PI Point data as soon as it closes the corresponding even...
Rafael Batista 1 day ago in PI Interfaces / Batch Interfaces 0 No status

Include MSXML with the latest version of the PI Interface for OPC XML-DA

The Read-Only version of the PI Interface for OPC XML-DA (1.7.3.40) does not contain the msxml4 library necessary for communicating with the OPC XML-DA. The workaround is to install the Read-Write version of the interface and then the Read-Only ve...
Randy Giguere 4 days ago in PI Interfaces / Other Interfaces 1 No status

PI EMDVB Interface should not use the STARTUP.dat to determine recovery start time when configured in Failover and running in RealTime mode.

Currently when the PI Interface for Emerson DeltaV Batch (EMDVB) is configured for failover and running in RealTime mode, the interface will use a recovery start time (RST) based on the last time the interface was active. This results in the inter...
Bethany Jewett 11 months ago in PI Interfaces / Batch Interfaces 2 Planned

ICU startup on high latency networks

On high latency networks, it can take ICU many minutes to start because every interface on the PI Data Archive is checked. Minimize startup time by caching a node's registered interfaces.
Guest over 2 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 10 Future consideration

PI Interface for OPC UA

While it is understood that adapters are the future of data source connectivity; there is an immediate need for existing PI system users (especially in the Chemical industry) to transition their data sources from using OPC DA to OPC UA. Many of th...
Brian Rock almost 2 years ago in PI Interfaces / General 0 No status

Remote PI ICU

Regardless of where interface info are stored (PI Module DB or AF), it would be useful to have a remote client tool allowing administrator users to configure interfaces  like they do with tags and AF objects. Today when you have to change con...
MAl over 2 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 2 No status

Migrate the PI ICU settings away from the PI Module Database

PI ICU settings are currently the main reason why the PI Module Database continues to live on even the most up-to-date PI systems. Please consider migrating the PI ICU settings from the PI Module Database to the PI Asset Framework or a separate fi...
Kenneth Barber over 2 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 5 No status

ICU> When the ISU instance is removed for a server, other interfaces were not properly detecting that and were behaving as though there was still an ISU instance for that server

ICU> When the ISU instance is removed for a server, other interfaces were not properly detecting that and were behaving as though there was still an ISU instance for that server. There are documented known issues related to the slow ICU loading...
Guest about 1 month ago in PI Interfaces / Other Interfaces 0 No status

Store bad quality from OPC server

Enhance the OPC DA Interface to store bad quality values from his OPC Server in PI, so that the values, timestamp and status from bad quality data are saved in PI.  Note: This was previously Enhancement 114636.
Guest over 2 years ago in PI Interfaces / PI Interface for OPC DA 2 No status

Update EFGen Interface Health Tags To Allow For Better Status Monitoring

The current EFGen interface "Status" health tag displays a value of "Good" if it is connected to the data source but does not factor in if it is writing Event Frame data to PI. There is not currently a straightforward way to drive a PI Notificatio...
Guest over 2 years ago in PI Interfaces / Batch Interfaces 2 No status