To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Search results: AVEVA™ Adapters

Showing 41 of 780

Design some UI for PI Adaptors

Design some UI for PI Adaptors, so it will be user friendly to configure the data source or data reading configurations etc. It is really hard to configure or troubleshoot an issue in PI Adaptor without Proper UI.
PradeepKumar Logandurai about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 1 No status

Configuration reconnection (retry) time on the adapter

OPC UA adapter takes 5min by default to reconnect to a load balanced PI Web API pair which failed over.
Guest 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Classic Mode for Adapters

One of the big issues we have with adapters (outside of the lack of write capability) is not having the same control over creating and editing tags that we have with PI interfaces. As we talked about the adapter automatically creates PI tags or us...
Brian Rock over 2 years ago in AVEVA™ Adapters / General 5 Future consideration

PI Adapter for OPC UA should preiodically retry to subscribe to each node for which subscription failed at startup

Currently the PI Adapter for OPC UA tries to subscribe to all the OPC UA nodes configured in the Data Selection configuration at startup. However, when as issue occurs during the subscription to an OPC UA node, that node will not be included in da...
Bernard Lafrance almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
sahilp over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 4 In development

Detect and monitor which OPC UA server the PI Adapter is connected to

When configuring a PI Adapter to leverage server-level redundancy, it is not currently possible to monitor which server instance the PI Adapter is connected to. Surfacing this information would allow server administrators to better monitor the hea...
Giulio Cattarin over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration

Add another Archive Mode option for the PI Interface for UFL

There should be a way to configure the PI UFL interface to both discard duplicate events (same value at the same timestamp) and record multiple unique values for the same timestamp when these events come from multiple data files. For example, if...
Guest over 3 years ago in AVEVA™ Adapters / General 0 Tell us more

Support of complex streams with PI Adapter for RDBMS with free attribute selection

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 2 Planned

Remotely Deploy/Manage Edge System Software

Remote management of Edge System software (Edge Data Store (EDS) and PI Adapters). The ability to deploy, configure, upgrade, and support these systems remotely.
Ryan McErlean over 3 years ago in AVEVA™ Adapters / General 2 Completed