Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Remove the dependence on .NET Framework

According to the documentation, the PI To CONNECT Agent requires both .NET Framework and .NET to be installed, which is odd since .NET is the successor to .NET Framework and so, in theory, you should need only .NET. Perhaps this shows that the PI ...
Kenneth Barber 42 minutes ago in PI to CONNECT / General 0 No status

The “Bad: No PI Data Archive Configured” status is misleading when the PI to CONNECT agent is intentionally set up for Usage Reporting only.

PI to CONNECT agent is intentionally set up for Usage Reporting only. If no PI DA is configured for transfer it can show Bad, even though tag usage reporting is working. If you expand the agent Description, it should indicate that data transfer is...
Guest 26 days ago in PI to CONNECT / General 0 No status

PItoPI: Exception reporting is bypassed without /SN parameter

The PI to PI interface bypasses exception reporting when moving data from source to destination PI server. The alteration to the PI to PI architecture should be rectified in the next update of the PI to PI interface. There is an existing KI for th...
Timothy Grindstaff 3 months ago in PI Interfaces / PI to PI Interface 2 No status

Replication of tag attributes

Provide the possibility to manually select replication of tag attributes as stream metadata. Besides None, Low, Medium, High in the Stream Metadata Replication Policy of a transfer there should be a "Custom" option to select additional tag attribu...
Hans-Otto Weinhold 4 months ago in PI to CONNECT / General 0 No status

1:1 Data Transfer Option in AVEVA PI2PI Interface

The AVEVA PI2PI Interface requires a new configuration option to enable a direct 1:1 data transfer from the source to the destination. This option must ensure that data is copied precisely as it is received from the source, without any modificatio...
Erik Prins over 1 year ago in PI Interfaces / PI to PI Interface 0 No status

Include more details in Transfer Health Stream

The TransferStatus property of the Transfer Health Stream currently does not show warning messages generated during a transfer. It is limited to messages like "Stopped", "Started" or "Initializing". This makes it difficult for end users to detect ...
Derek Wong 4 months ago in PI to CONNECT / General 0 No status

Store bad quality from OPC server

Enhance the OPC DA Interface to store bad quality values from his OPC Server in PI, so that the values, timestamp and status from bad quality data are saved in PI.  Note: This was previously Enhancement 114636.
Guest about 4 years ago in PI Interfaces / PI Interface for OPC DA 2 No status

Allow Multiple Data Archives per PI to CONNECT Agent

Allowing data transfer for tags from multiple PI Data Archives with one agent will help to cut down on the number of agent services, and therefore machines, that need to be involved to send data from PI to CONNECT.
Guest about 4 years ago in PI to CONNECT 0 In development

OPC interface retries sending InstrumentTag/ItemID to OPC Server

The idea is to have PI Interface for OPC DA/HDA to be able to send again Instrument Tag/Item ID after a configurable time when OPC Server is not able to resolve it (AddItem failed). This would be a workaround for an OPC server issue and would help...
Guest about 4 years ago in PI Interfaces / PI Interface for OPC DA 3 No status

OSIsoft Python Library for data science

As a data scientist, I would like to be able to use a fully supported OSIsoft Python library without having to directly interface my Python script with a middleware. This OSIsoft Python library would be able to perform the same operations as PI Da...
Guest about 4 years ago in AVEVA™ PI System Access (PSA) / General 3 No status