To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 13 of 5194

Allow configuration option to export PI Tags to Excel separated by a row or column to allows for timestamp information

My Customer, Southern California Edison, would like to have an option in Excel that would automatically include a blank row or column (depending on the output settings configured) so that they can export a few hundred tags, and then be able to req...
Janelle Minich 13 days ago in AVEVA™ PI DataLink™ / Format 0 No status

Use DisplayDigits attribute in formatting of cells

Use DisplayDigits attribute in formatting of cells. Note that hitting F9 will not reformat the cells if a change to the displaydigits is made. That includes if you change the tagname to a tag which has a different display digits attribute. Note: ...
Guest over 3 years ago in AVEVA™ PI DataLink™ / Format 0 Declined

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Alexa Derago 3 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

configure the PI DataLink language independently of the Microsoft Office language setting.

"Beginning with PI DataLink 2022 it uses the Office language to display the localized functions." Because the customer’s organization operates globally, individual users may have different Office language settings. To maintain consistency, they wo...
Runpu YAN about 2 months ago in AVEVA™ PI DataLink™ / Format 0 No status

Return the Values of Timestamp Data Items in Timestamp Format

The values of timestamp tags or AF attributes should be formatted as timestamp in Excel by default. Currently they are returned as integers, and then users have to manually convert them into timestamps.
Guest over 3 years ago in AVEVA™ PI DataLink™ / Format 0 Declined

Better behavior on Brazilian DST start (no midnight)

Whenever Daylight Saving Time starts on Brazil the issue below is prone to happen: Whenever Start/End time has a date corresponding to DST start, which will either cause date misinterpretation (using formats XX-XX-XX or XX/XX/XX) or throw an err...
Guest over 3 years ago in AVEVA™ PI DataLink™ / Format 0 No status

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Mario Amrhein about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Format based on Questionable attribute

Would like to be able to format any data value based on the questionable attribute. Use case: We have a report that uses 15 minute sampled data. The data is in a large table, one month displayed, date on the left hand side, time in 15 min incre...
Guest over 3 years ago in AVEVA™ PI DataLink™ / Format 0 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Matthew Kishe almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration