To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 148
344 VOTE

Connector-level Failover - OPC UA 2.x

Support connector-level failover in PI Connector for OPC UA 2.x (relay-enabled version). Similar to UniInt failover (interfaces), failover should be data source specific and always favor the data source in the better state.
Gabriel Verreault over 3 years ago in PI Connectors / PI Connector for OPC UA 35 Declined

OPC UA server failover based on watchdog tag

Gen2 PI Connector for OPC UA support OPC UA server level failover. How the Connector determine when to failover to the other OPC UA server: As per 6.6.2.4.2 ServiceLevel , this is used by the client to determine whether to connect/disconnect fro...
Ee Sheing Lee 30 days ago in PI Connectors / PI Connector for OPC UA 1 No status
118 VOTE

PI OPC UA Connector Array support

Add reading capability for OPC UA Arrays. Currently items with “ValueRank“ = 1 are ignored.
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 11 No status

Retrieve data even it's not changed on OPC server

Currently Connector configured to rertieve event on change and not based on a scan class like interfaces.The Connector suscribes to the changes, and when a change comes in to the server, the data will be sent to PI connector. We need option to ret...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 13 Declined

Do not synchronize description from OPC UA server into PI Tag

There are situations when customer prefers to use “description” in PI Tag attribute that is independent from item “description” provided by OPC UA Server.   Currently, during each synchronization, the OPC UA Connector synchronizes descri...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 10 In development

PI to Connect Agent instance Failover

on behalf of customer: We would like to see agent failover added to PI to Connect. The PI System already provides high availability, and extending this capability into PI to Connect would deliver a resilient hybrid infrastructure end-to-end. Histo...
omar alomari 29 days ago in PI to CONNECT / General 0 No status

Allow different permission models and "view effective permissions for user" features within tenant

For sharing data to external clients who are not PI/CONNECT users, we cannot use the community sharing and permissions model and instead have to add users to an org's tenant. By default, all users are granted the tenant member and tenant viewer ro...
Adam Bolin 16 days ago in PI to CONNECT / General 0 No status

OPC UA: allow historical data access

allow historical data access with custom time ranges, like OPC HDA
Clint Ramsey over 3 years ago in PI Connectors / PI Connector for OPC UA 11 Declined

Get data by polling

Support acquiring data by polling the OPC UA server rather than subscription.
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 4 Declined

PI to CONNECT should have a verification tool to make sure there are no gaps in the data

When using PI to CONNECT there might be errors in the transfer due to disconnections or other network issues. Ideally PI to CONNECT would have a tool to verify if the data was properly transferred by checking the data.
Fabio Dani 4 months ago in PI to CONNECT / General 0 No status