To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 253

PI Adapters should handle good NULL Values like PI Connectors and submit to the archive

A PI Connector reading a Null value in good quality send it to the Archive A PI Adapter skip the value, this gives in the archive a wrong picture. please enable the PI Adapter to submit also Null values with good quality to the archive like PI Con...
Markus Rombach 1 day ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Enable AVEVA Adapter for OPC UA to work with OPC UA Servers that only allow Dynamic Addressing and Virtual Browsing

Some OPC UA Servers have the concept of Dynamic Namespace Addressing and Virtual Browsing. The UA Nodes do not exist in the OPC UA Address Space. Nodeids are created\added to the Address Space only when a Client makes a request for the NodeIds thr...
Vaskar Dahal 12 days ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status
138 VOTE

Referencing attributes on other Elements for PI Notifications 2016 Message

Request : Being able to show Attribute values from other Elements other than the attributes on the Referenced Element for the Message in Notification 2016. Description : From the old version, it was possible for a notification message to display ...
Guest over 3 years ago in AVEVA™ PI Server / Notifications 9 No status

Configurable Hostname/IP Identifier for OMF Health Egress

The health tags and AF structure is created with the following naming pattern by default: <machine hostname>.<adapter type> To support modern containerized deployment models, please consider adding a configurable field that allows cust...
Bharat Rawat 13 days ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status
111 VOTE

List all Notifications and its subscribers

Managing thousands of notifications can be difficult. There should be an option to export all the notifications and its subscribers. In PI Builder, you can find information about notifications via Contacts and Elements. There should be a direct wa...
Guest over 3 years ago in AVEVA™ PI Server / Notifications 10 No status

Editing analysis templates should not clear notification trigger conditions.

Currently, if you have notification rules that are triggered by an event frame analysis template with additional attribute-based trigger rules, those additional attribute-based trigger rules get cleared any time you update the analysis template. T...
Kevin Wood 13 days ago in AVEVA™ PI Server / Notifications 0 No status

Allow REST config tool to generate json text for the user

In addition to the "test send" button, the JSON generation tool should have a "view JSON" button that generates the actual JSON body that PI will send. This will make troubleshooting much easier, and give users better understanding of things like ...
Kevin Wood 13 days ago in AVEVA™ PI Server / Notifications 0 No status
106 VOTE

PI Adapter for OPC UA should be able to write outputs to the OPC UA Server

The PI Adapter should be able to create a data pipe listener on certain streams (unsolicited reads) that would trigger the writes back to the OPC UA Server. This is useful when providing set points to the equipment without the need of establishin...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 9 Future consideration

Start/stop components to be retained on restart

Currently it is possible to stop a component for a running adapter. However, if the adapter is restarted the component will automatically start up. It would allow for extra control during commissioning, downtime, incidents, etc. to be able to disa...
Mike Horrocks 4 months ago in AVEVA™ Adapters / General 0 No status

It would be great to have an option to backfill/recalculate Event Frame analysis without sending notificaiton.

I know, that notifications are not sent for event frames older than 72 hours, but that 3 days is still too long. Usually we just want to recalculate  Event Frames to have a proper statistic about the past in reports. The notification is use...