To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Connectors

Showing 318

Retrieve data even it's not changed on OPC server

Currently Connector configured to rertieve event on change and not based on a scan class like interfaces.The Connector suscribes to the changes, and when a change comes in to the server, the data will be sent to PI connector. We need option to ret...
Guest over 1 year ago in PI Connectors / PI Connector for OPC UA 11 No Status

PI OPC UA Connector Array support

Add reading capability for OPC UA Arrays. Currently items with “ValueRank“ = 1 are ignored.
Guest over 1 year ago in PI Connectors / PI Connector for OPC UA 11 No Status

Add possibility to Configure purge time/output path/REST channel authentication in the admin/ui webpage without GlobalConfig.ps1

It's more complex and not the safest way to change the PurgeTime and OutputPath parameters with GlobalConfig.ps1 by specifing password in command line. It would be better if this option would be availble for UFL admin on the admin/ui webinterface....
Yuriy Sadovskiy 9 days ago in PI Connectors / PI Connector for UFL 0 No Status

Support HTTP Token Authentication to a REST Endpoint

The REST endpoint from which I want to pull data requires token authentication. I would like the UFL Connector to be able to obtain the token given the username and password I enter on the Admin page.
Guest over 1 year ago in PI Connectors / PI Connector for UFL 6 No Status

Control which PI/AF servers each data source sends data to.

Right now, for one instance of the connector, all configured data sources will send data to all configured PI Data Archives and PI AF Servers. It is all or nothing. Due to the fact that you cannot have multiple instances of the same connector on a...
Guest over 1 year ago in PI Connectors / General 0 No Status

PI System Connector - Support failover at the data source level

PI System Connector should be data source (collective aware) specific and always favor the data source in the better state. Furthermore, the PI System Connector should be able to determine whether data is stale on a given collective member, and au...
GaryYegiazaryan about 2 months ago in PI Connectors / PI System Connector 1 No Status

Connector level failover - PI System Connector

Support connector-level failover in PI System Connector. Similar to UniInt failover (interfaces). Failover options should support hot, warm and cold failover.
GaryYegiazaryan about 2 months ago in PI Connectors / PI System Connector 1 No Status

Ability for PI Connectors to create future data point

Add the ability for PI Connectors to create future data point. This is especially useful for the PI Connector for UFL. The current workaround is to manually create the point as a StoredValues=FutureData.
Gabriel Verreault over 1 year ago in PI Connectors / General 0 No Status

OPC UA: Set PI Tag Zero and Span Based on OPC UA Range

For OPC UA Analog Items, the OPC UA standard mandates an EURange property and an optional InstrumentRange property. These Range properties contain a Low and High field.The PI Connector for OPC UA should have an option to use either of these Ranges...
Guest over 1 year ago in PI Connectors / PI Connector for OPC UA 0 No Status

Allow the data type of PI Points to be set manually with PI connector for OPCUA

[Background]We know that when use PI Connetor for OPCUA, the data type of the PI Point is synchronized with the OPC server settings. But we would like to set deferent one.e.x.) -Datatype of OPC Server tag : "String" -Data type wanted to be set for...