To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Convert PI Builder from a COM add-in to an Office Add-in

This change will bring a few benefits: PI Builder will become more secure. COM add-ins use ActiveX, and ActiveX is both deprecated and not secure. PI Builder will become cross-platform. AVEVA will be able to publish PI Builder to the Microso...
Kenneth Barber 3 months ago in AVEVA™ PI Server / PI Builder 0 No status

Add configurable defaults for PI Point "Pointsecurity" and "Datasecurity"

Read access to the PIPOINT table is required for most identities. Pointsecurity and Datasecurity currently use the settings on the PIPOINT table as the default. New points will generally give read access to most identities because of these default...
Guest about 4 years ago in AVEVA™ PI Server / Security 3 No status

Allow multiple instances of an AVEVA Adapter to exist on the same server without using Docker

Currently, there can be only 1 instance of a specific AVEVA Adapter on each server if Docker is not used. However, within that instance, multiple components and data sources can be configured. This is convenient, but then the service account for t...
Kenneth Barber 3 months ago in AVEVA™ Adapters / General 0 No status

PI Batch Interfaces (EFGEN) Performance Counters Reliability

The Batch interfaces currently handle performance counters configuration extremely unreliably. To explain: Performance counters are not allowing naming convention to be applied and are forcing hard-coded tags naming giving rise to conflicts betw...
Moshe Sabag 6 months ago in PI Interfaces / Batch Interfaces 0 No status

PI Adapters should handle good NULL Values like PI Connectors and submit to the archive

A PI Connector reading a Null value in good quality send it to the Archive A PI Adapter skip the value, this gives in the archive a wrong picture. please enable the PI Adapter to submit also Null values with good quality to the archive like PI Con...
Markus Rombach 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status

Prioritize user-friendliness over reflecting the configuration file

Currently, the AVEVA Adapter Configuration Utility is a program that lets you enter data into the configuration file without having to type parameter names and while having some protection against invalid inputs (e.g. a check box for true/false va...
Kenneth Barber 3 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Improve Data Cache Performance by parallelizing Data Archive update fetches

Currently, when the Data Cache is signed up for updates on multiple data archives, updates from each archive are fetched in series, one after another. When there are many data archives involved (especially if they are geographically dispersed) thi...
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

Percentile function

As a user of analyses, I would like to have a Percentile function so that I can filter out atypical events when doing summary calls. The function would look like this: Percentile('attribute', 'timerange', value). This is related to enhancement req...
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 4 No status

Export Data Supports Data Frequency

As a process engineer, I would like to be able to control the data frequency (minute, hour, etc.) of how much data is exported for my time range rather than a fixed number of data points SO THAT the data that I export can actually be used for some...
Guest about 4 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 3 No status

Migrate the PI ICU settings away from the PI Module Database

PI ICU settings are currently the main reason why the PI Module Database continues to live on even the most up-to-date PI systems. Please consider migrating the PI ICU settings from the PI Module Database to the PI Asset Framework or a separate fi...
Kenneth Barber about 4 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 5 No status