To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 201 of 5192

Enable Adapter for OPC UA to use the Pub/Sub method

Pub/Sub is proposed to be a more efficient and scalable method of transferring data using OPC UA. Allowing the adapter to access data in this way would increase the options for data collection, and allow the OPC UA adapter to be used in many more ...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Possibility to add more than 2 most recent points to XY Plots for better analysis

We would like the possibility of configuring more than 2 most recent points in XY plots to better understand the trend of equipment readings in the past. A better comparison can be made with recent points with different colors and more data in the...
Guest over 3 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 0 No status

Remove limit for Asset Based calculations

Allow users to remove the limitation on the number of events PI Vision allows for asset based Ad Hoc Calculations.
Guest over 3 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 1 No status

Support StdDev as a summary statistic in PI Vision trends and ad hoc displays

The ability to see Std Dev in PI ProcessBook ToolTips is missing in PI Vision. It would be useful in ad hoc displays to be able to quickly add or see the Std Dev without multiple configuration steps.
Guest over 3 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 0 No status

PI Adapter for GE e-terrahabitat/HabConnect

We need a new robust product to support data transfer between GE e-terrahabitat/HabConnect and PI. This product would need to support the following: Highly available remote management/deployment multiple instances on a single node (to support larg...
GaryYegiazaryan over 2 years ago in AVEVA™ Adapters / New Connectivity 0 No status

PI Adapter for OPC UA should send the previous value when it has been with the same value for a long time

"This enhancement request proposes a solution to address the issue of data interpolation between two values far apart in time in adapter data collection. The suggestion is to include the value right before the new data point, ensuring the fidelity...
Fabio Dani over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

More control on MQTT parameters on the AVEVA Adapter for MQTT

It would be nice to have more control on additional MQTT parameters for the AVEVA Adapter for MQTT. We are especially interested in having control on the QoS of the subscription. Setting this would give us more control in buffering, especially whe...
Tombayu Hidayat about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

API to check Adapter buffer statistics

We can check buffer statistics with PI Buffer subsystem (pibufss -cfg, qs) and also with PI Connector/Relay, to verify whether Buffer is healthy, events in queue and etc.Adapter does not has any API to check this.
Ee Sheing Lee about 2 years ago in AVEVA™ Adapters / General 0 No status

Allow export of summary statistics

No way to export summary statistics (Ad hoc trend min/max/etc)
Laurie Dieffenbach about 1 year ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 0 No status

Add Standard Deviation and Difference to Summary Table of the Ad Hoc Workspace

This helps with basic statistical analysis, and supplements statistics already there (average, minimum, maximum). Process Engineers and other analyst-type roles would use this. The Difference is between the ending and starting values of the trend.