To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 570 of 5273

Support derived templates

When replicating AF data to CONNECT, I would like to make sure that all assets configured from templates which are themselves based on derived templates, preserve the template inheritance. For instance, if I have a Mobile Equipment template, with ...
Max McKay over 1 year ago in PI to CONNECT / General 0 No status

Add option to specify Calculation Basis in PI Vision Calculations

Add a configurable option for Calculations in PI Vision to specify a Calculation Basis of Continuous or Discrete when performing summary calculations. Due to a limitation on the PI Data Archive, PI Vision summary calculations currently can treat ...
Guest over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

DeltaV Smart Connector Update to OPC UA

The newest release of DeltaV has the capabilities of enabling an OPC UA server that could be used to transmit realtime date from DeltaV to the PI database. Right now, the interface between the two systems uses OPC DA. With DeltaV's plan to migrate...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 3 No status

PI Connector for IEC 60870-5-104: to filter IOAs

Considering the following scenario encountered by the customer: In IEC-104 data source, there might be 500 signals of single point (type=1, M_SP_NA_1) and 1000 measurements of normalized value (type=9, M_ME_NA_1); however the customer would not l...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 3 No status

Configure PI to CONNECT Transfer Configuration via CSV or other file import

In addition to building the transfer list via searching a data archive, it would also be good to allow the user to reference a file (e.g. CSV) that has a list of points to transfer.
Guest over 3 years ago in PI to CONNECT 3 No status

PI to CONNECT - AF Lookup Table Support

Support AF lookup table information on PI to CONNECT.
Guest over 3 years ago in PI to CONNECT 0 No status

Calculated tags present value error

For calculated tags when being trended for more than ~12 hours time frame, the trend works fine except for the live present value, the calculation can be completely off. See attached screenshot for an example, where several tags are checked whethe...
AbdulRahman.Maskari 6 months ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Editing PI Calculations/Asset-based Calculations in Bulk

Provide a more efficient way to edit the expressions in multiple calculations.
Jeccie Qiu about 1 year ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Reduce Number of Point Sources for PI Connector for PI System Health

PI Connector for PI System Health creates a LOT of different point sources for the Pi points it creates on the Data Archive. Some customer may prefer to not have so many point sources show up for one interface/connector. Adding a method to reduce/...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 2 No status

Warm and cold PI Connector for OPC UA failover

Currently only hot failover is featured for the PI Connector for OPC UA but this creates a lot of strain on the data sources. We need to be able to select warm/cold failover mechanism.
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status