To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 158 of 5192

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...
Timur Eroglu almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Sampling/Publishing Interval parameters to be part of Data Selection description

When configuring the AVEVA Adapters in general, we would find more convenient to be able to define the ‘Sampling Interval’ and 'Publishing Interval' parameters inside the ‘Data Selection’ configuration per each data stream. For instance, when desc...
Christian Leroux over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

The Adapter framework needs to be able to perform scaling on raw data

Many users want to use Adapters for the nre abilities they offer versus Interfaces: Support for containers, Linux, edge deployment, new failover and fault tolerance, integration with CONNECT Data Services, etc. HOWEVER, many sites use Interfaces t...
Daniel Lopez 5 months ago in AVEVA™ Adapters / AVEVA Adapter for DNP3 1 Future consideration

Provide migration from PI BatchView

Provide a migration from PI Batchview displays in PI ProcessBook to PI Vision.
Guest over 3 years ago in AVEVA™ PI Vision™ / Event Comparison Displays 4 No status

Support outputs/write data from PI Adapters

No description provided
Allison Muraski over 3 years ago in AVEVA™ Adapters / General 4 No status

Allow setting interpolation type in Adapters

We would like to be able to specify the interpolation type (linear vs step) when Adapter creates tags in Archive.
Damon Vinciguerra 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Vision Event frames should show child elements in the Attributes panel of the Events comparison page.

When viewing event comparisons, the Attributes pane only lists the event frame attributes, the referenced element, and the referenced element's attributes. It currently cannot drill down and trend child element's attributes.
Guest over 3 years ago in AVEVA™ PI Vision™ / Event Comparison Displays 0 No status

Event Comparison: Add ability to set time range / end time (X-axis)

Sometimes there are very long event frames in the event comparison and it would be nice to be able to set the width of the x-axis to cut these event frames off at a certain duration. It's inconvenient to have to manually exclude them, and sometime...
Guest over 3 years ago in AVEVA™ PI Vision™ / Event Comparison Displays 3 No status

PI Adapter for AspenTech IP21

We have customers who are using AspenTech IP 21 and would like to have data replicated in both PI DataArchive and OCS in the future. Since the PI Interface is a bit outdated, a new PI Adapter would make perfect sense (since there is already a PI C...
Guest over 3 years ago in AVEVA™ Adapters / New Connectivity 4 Tell us more

Support "Data Handling" options for adapters

The PI Interface for OPC DA can write IO timeout when it cannot get values from the OPC server. It would be useful to have the same option for the adapters so that stale data is marked IO timeout or similar, and automatically invalidates calculati...
Mike Horrocks 10 months ago in AVEVA™ Adapters / General 1 No status