To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 507 of 5192

PI OPC UA Connector - point attribute based configuration

We are just starting the first tests with PI OPC UA Interface. We notice that the classic method of tag configuration, known from the interface, is no longer possible. This is probably due to the connector concept. Unfortunately, this does not fit...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Make trend legend optional

Add the ability to remove/disable the trend legend
Guest over 3 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 3 No status

Allow the connector to use a proxy for web requests

Provide a way to configure the connector to use a proxy and authenticate with the proxy if required.
Guest over 3 years ago in PI Connectors / PI Connector for UFL 4 Declined

Allow specification of PI Point Attributes set by the PI Asset Connector for Emerson DeltaV 3.X

The PI Asset Connector for Emerson DeltaV 3.X sets PI Point Attributes either based on the values in the enterprise historian configuration file (EntHist.xml) or based on default values. It would be useful to have the option to adapt the PI Point...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 2 No status

Support for Alarms and Conditions

We need to be able to handle Alarms and Conditions into the PI system. We are moving away from OPC classic into OPC UA.
Hobbe over 3 years ago in PI Connectors / PI Connector for OPC UA 7 Declined

Color scheme for color blind

It would be very helpful to have an option to select a color scheme for color blind e.g. change all red trends to color that have not been used and classified as good color for color blind.
Guest over 3 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 1 No status

Apply the Connector Relay to IEC 60870-5-104 Connector

Adding the Relay and the DCM framework to the "legacy"IEC 104 Connector in order to improve the architecture management and security
marcogiunti over 3 years ago in PI Connectors / Other specific PI Connector 1 Declined

Get Description from the OPC UA Server into the AF attribute

Get Description from the OPC UA Server into the AF attribute
Gabriel Verreault over 3 years ago in PI Connectors / PI Connector for OPC UA 0 Declined

Prevent OPC UA Connector 2.x from doing Data Discovery in Tags-Only mode

Use case: If we are frequently adding OPC UA tags and OPC UA server has a large variable count, then each discovery will increase the amount of time for it to complete. This increases the amount of time needed to discover the data source + configu...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 0 Tell us more

PI Connector for IEC 60870-5-104 bi-directional between SCADA and PI

RWE Power AG “But one really important feature we need, is the ability to write back from PI into the SCADA system Until now, we couldn’t find anything about this (important) functionality. So our question is if we can use this connector bi-dire...
Guest over 3 years ago in PI Connectors / General 4 Declined