Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 474 of 5288

Request for Radar Plots

A radar chart is a graphical method of displaying multivariate data in the form of a two-dimensional chart of three or more quantitative variables represented on axes starting from the same point. The relative position and angle of the axes is typ...
Guest over 3 years ago in AVEVA™ PI Vision™ / Symbols 5 Declined

Pi adapter OPCua able to rename pi-tags

As per title
Rob Chew 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Tell us more

Trend: Logarithmic Scale

in some of our processes, we have pressure close to vacuum. in this case we need a logarithmic scale. until now, it's not possible to configure PI Vision trends with a logarithmic scale.
FranzK over 3 years ago in AVEVA™ PI Vision™ / Symbols 6 Declined

Add "Sequence of Events" Symbol Type

Add a table symbol which consists of the following 3 columns: Tag Name Tag Value Tag Timestamp (default sort on this column, ascending order) This table would consist of a set of tags over a specified time range. The purpose of this "Sequence ...
Guest over 3 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Embed video to PI Vision Display

As PI Vision user I would like to embed critical process equipment's video to our PI Vision Displays so that I can see how the equipment is functioning in real-time.
Guest over 3 years ago in AVEVA™ PI Vision™ / Symbols 5 No status

Allow PI Adapter for MQTT (Generic) to process non-json payloads

Some MQTT devices do not send json payloads; for example, some devices send a single value as the payload for a specific topic. It would be beneficial for the adapter to be able to handle this rather than to convert these payloads into json befo...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 3 In development

Embedded Symbol Builder

A PI Vision symbol for user to build their own symbol (i.e. Waterfall chart, radial gauge) through symbols
Karthigesan Velautham about 1 month ago in AVEVA™ PI Vision™ / Symbols 0 No status

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Damon Vinciguerra 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Andrew Miu 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Planned

Error handling for OPC UA Server nodes with "Null" data type

Using a combination of Honeywell Experion OPC UA and the Aveva OPC UA Adapter, we have observed that when an instrument physically fails in the field or goes offline / stops sending communication to the Experion server, it may appear in the Honeyw...
ChrisMcKee 3 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status