To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 543 of 5273

OPC UA - Add Option to not browse item before creating a monitored item

Need an option in Tag only Mode to force connector to create a monitored item without browsing item. Some OPC servers require creating a monitored item BEFORE the item can be browsed.
JTWhite over 1 year ago in PI Connectors / PI Connector for OPC UA 0 No status

Support derived templates

When replicating AF data to CONNECT, I would like to make sure that all assets configured from templates which are themselves based on derived templates, preserve the template inheritance. For instance, if I have a Mobile Equipment template, with ...
Max McKay over 1 year ago in PI to CONNECT / General 0 No status

Prevent users from opening display if they don't have access to data

If a user does not have access to any of the data items (tags/attributes) on a display, they should not be able to open that display.
Ryan McErlean over 3 years ago in AVEVA™ PI Vision™ / Security 0 Declined

Allow users to request access to data

If a user doesn't have access to view the data associated with data items (tags/attributes) on a display, provide a way for them to be able to request access to the data.
Ryan McErlean over 3 years ago in AVEVA™ PI Vision™ / Security 0 Declined

DeltaV Smart Connector Update to OPC UA

The newest release of DeltaV has the capabilities of enabling an OPC UA server that could be used to transmit realtime date from DeltaV to the PI database. Right now, the interface between the two systems uses OPC DA. With DeltaV's plan to migrate...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 3 No status

PI Connector for IEC 60870-5-104: to filter IOAs

Considering the following scenario encountered by the customer: In IEC-104 data source, there might be 500 signals of single point (type=1, M_SP_NA_1) and 1000 measurements of normalized value (type=9, M_ME_NA_1); however the customer would not l...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 3 No status

Configure PI to CONNECT Transfer Configuration via CSV or other file import

In addition to building the transfer list via searching a data archive, it would also be good to allow the user to reference a file (e.g. CSV) that has a list of points to transfer.
Guest over 3 years ago in PI to CONNECT 3 No status

PI to CONNECT - AF Lookup Table Support

Support AF lookup table information on PI to CONNECT.
Guest over 3 years ago in PI to CONNECT 0 No status

Reduce Number of Point Sources for PI Connector for PI System Health

PI Connector for PI System Health creates a LOT of different point sources for the Pi points it creates on the Data Archive. Some customer may prefer to not have so many point sources show up for one interface/connector. Adding a method to reduce/...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 2 No status

Warm and cold PI Connector for OPC UA failover

Currently only hot failover is featured for the PI Connector for OPC UA but this creates a lot of strain on the data sources. We need to be able to select warm/cold failover mechanism.
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status