To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 317 of 5194

Trend: Logarithmic Scale

in some of our processes, we have pressure close to vacuum. in this case we need a logarithmic scale. until now, it's not possible to configure PI Vision trends with a logarithmic scale.
FranzK over 3 years ago in AVEVA™ PI Vision™ / Symbols 6 Declined

Add "Sequence of Events" Symbol Type

Add a table symbol which consists of the following 3 columns: Tag Name Tag Value Tag Timestamp (default sort on this column, ascending order) This table would consist of a set of tags over a specified time range. The purpose of this "Sequence ...
Guest over 3 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Embed video to PI Vision Display

As PI Vision user I would like to embed critical process equipment's video to our PI Vision Displays so that I can see how the equipment is functioning in real-time.
Guest over 3 years ago in AVEVA™ PI Vision™ / Symbols 5 No status

OPC interface retries sending InstrumentTag/ItemID to OPC Server

The idea is to have PI Interface for OPC DA/HDA to be able to send again Instrument Tag/Item ID after a configurable time when OPC Server is not able to resolve it (AddItem failed). This would be a workaround for an OPC server issue and would help...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 3 No status

Improve Attribute Filter Logic in Asset Comparison Table to Distinguish Between Digital States and Numeric Values

In PI Vision, when using dynamic search criteria in an Asset Comparison Table, attribute filters such as "Drive_G >= 15" can produce misleading results because PI Vision does not differentiate between digital states and actual numeric values. D...
Guest 6 months ago in AVEVA™ PI Vision™ / Symbols 0 No status

Show transparent shapes in design mode

When modifying a display you cannot see where transparent shapes are. If they could be made visible when in design mode it would be far easier to maintain displays.
Mike Horrocks 7 months ago in AVEVA™ PI Vision™ / Symbols 0 No status

FFT Trend

Please provide a FFT (Fast Fourier Transform) frequency analysis trend. Best case scenario would be to right click (or otherwise select) a trend trace and convert back and forth between FFT and linear trends. It is indispensable for troubleshootin...
Pete Long over 3 years ago in AVEVA™ PI Vision™ / Symbols 5 Declined

Map Symbol

Map symbol that shows assets and data on a map based on GPS location. Ability to detect movement using location coordinates (latitude/longitude) attributes / compare trips by path taken using a map symbol.
Guest over 3 years ago in AVEVA™ PI Vision™ / Symbols 6 Declined

Add PI Vision display option to show XY plot Regression line equation

In PI Vision 2019, it is now possible to add a regression line to an XY plot (See: User Guide PI Vision 2019>XY Plot>Format data pairs for an XY plot) However there is no way to see the equation of this line. In PI ProcessBook it was possibl...
Guest over 3 years ago in AVEVA™ PI Vision™ / Symbols 3 No status

Enhance the OPC DA interface to avoid mixing polled and advise tags on the same scan class

The interface does not log any informational messages about polled and advise tags getting mixed up on a scan class. Currently it would detect that polled tags are part of scan class 1 and reject it and print the following: E 13-Apr-16 17:26:18 ...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status