To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Allow multiple traces to be selected at the same time in Configure Trend > Trace options

Allow selection of multiple Traces in the Trace Options, and allow modification of the Legend Label for all of them at the same time so they all have the same Legend Label configuration
Guest about 4 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Include Windows Counters/OMF Health for Message Log Event Rate

Having metrics that count the number of messages being written to the message log, and categorized by severity, gives a great dashboard overview of the status of PI data archive. For example, having a events/min count of error messages historized ...
Mike Horrocks about 2 years ago in AVEVA™ PI Server / Data Archive 0 No status

Allow PI AF Analyses to reference PI Vision dashboard start time

PI AF attributes can summarize other PI Point attributes across a time range using value retrieval methods and setting the "TimeMethod" parameter to "TimeRange". When a PI Vision dashboard references these summary attributes, it overrides the time...
Greg Malek 9 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Add option to exclude digital and string tags from the single scale type

On a trend with multiple traces when single scale type is selected, allow digital and/or string tags to still have custom range/scale settings. If there are multiple related traces that I want to auto range on a single scale, then having digital o...
Guest over 1 year ago in AVEVA™ PI Vision™ / Symbols 0 No status

Ability to re-size grouped symbols without un-grouping

It appears that you have to un-group symbols in order to resize them. As an example, we can have a symbol of a pump, the pi value of current pressure, and then a title tag all grouped together. It gets difficult to efficiently update displays when...
Borgh almost 3 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Multistate trend ranges

as you can with other symbols - have the colors of a trend line - change color as it passes through value ranges (defined in the configuration panel or from limits in PI AF)
Martin Bryant over 3 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

PI Notifications automated emails need to display all receivers of the automated emails from the PI Notifications application, not just the singular user (me in this case).

PI Notifications automated emails need to display all receivers of the automated emails in the list of emails that the automated email was sent to. It is very important for the user (or receiver of the automated PI Notification email) to understan...
Phil Jones almost 3 years ago in AVEVA™ PI Server / Notifications 1 No status

Segment PI Tag Delete Permissions

Want to be able to allow some users the ability to create and modify tags, but to avoid the issues with deleted tags being hard to recover or accidents, remove their ability to delete tags. Currently, PI Tag Security has only two options: Read/Wri...
PriceN over 1 year ago in AVEVA™ PI Server / Data Archive 0 No status

"Connect As" to the Analysis Service From PI System Explorer

The "Connect As" feature only changes the Asset Framework Connection and still uses the user who runs the application to connect to the Analysis service. This causes a confusion for end users as they cannot perform their analyses operations (e.g. ...
Mohammed Qasim Asghar 9 months ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Keep the vertical cursor position on Ctrl+z action on trend symbol

In processbook, when you position a vertical cursor and make a zoom, the cursor is maintained. When you hit CTRL+Z keys, you're back to the previous display with the cursor positioned In Pi Vision, when you position a vertical cursor and make a zo...
jerome.boudon about 3 years ago in AVEVA™ PI Vision™ / Symbols 0 No status