To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 396 of 5213

Transformation and Scaling for OPC UA Adapter

Implement transformation and scaling for OPC UA adaptor the way it exists for PI OPC DA interface tags. The user can modify egressed tags and the data will be transformed / scaled when egressed.
Guest over 3 years ago in AVEVA™ Adapters 3 Future consideration

PI Adapter for SNMP

Write a PI Adapter that supports the SNMP protocol and is capable of writing data to EDS, PI, and OCS.
Guest over 3 years ago in AVEVA™ Adapters / New Connectivity 3 Evaluating

Support URN in addition for URI for OPC UA Server redundancy

As stated in the documentation "Some OPC UA servers use URNs instead of URLs, which is not currently supported by this adapter.", adding support for URNs would increase the servers the adapter is compatible with.
Mike Horrocks 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Configuration reconnection (retry) time on the adapter

OPC UA adapter takes 5min by default to reconnect to a load balanced PI Web API pair which failed over.
Guest 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Adapter to failover when there is egress issue

When connection to the datasource are all good for all the adapter failover members, but the primary adapter having issue connecting to the PI web API (egress) for example, adapter does not failover. Unlike PI Interface UNIINT failover, when there...
Ee Sheing Lee about 2 years ago in AVEVA™ Adapters / General 2 No status

Classic Mode for Adapters

One of the big issues we have with adapters (outside of the lack of write capability) is not having the same control over creating and editing tags that we have with PI interfaces. As we talked about the adapter automatically creates PI tags or us...
Brian Rock over 2 years ago in AVEVA™ Adapters / General 5 Future consideration

Table: Support Different Table Styles

Similar to tables in Word / PowerPoint, support several different styling options for tables. Additionally, support the ability for a user to style a table exactly how they want it (with background fill colors, text colors, etc.).
Guest over 3 years ago in AVEVA™ PI Vision™ / Symbols 0 Declined

Trend: Time Range: Duration and Offset - Add option to support start time

Currently the Trend object's Time Range has a Duration and Offset option which will take the End Time of the display and a specified duration for the trend's timerange. We need to have the ability to do the same based on the Start Time and a durat...
Guest over 3 years ago in AVEVA™ PI Vision™ / Symbols 2 No status

Bring back column filters in event frame tables!

the column filters in event frame tables were great! with the addition of other attributes in tables, I was really looking forward to having column filters on these as well. this allows for much greater slicing of event frames and much better perf...
rfesler over 3 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Allow Default Scale Range To Be Set to "Database" for Trend Symbol

Need to create hundreds of trends and there are some defaults that are available but the scale range default is Autorange for the values being plotted and would be good if this could be changed to be Database limits by default when creating a new ...