Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 172 of 5219

MarkArchiveGaps tuning parameter description should be more descriptive

The description for the MarkArchiveGaps tuning parameter for a value of 2 is unclear. A user might interpret: 2 - Gap markers only when there is an actual gap between two consecutive archives. to mean that markers are shown when a tag does not h...
Guest over 3 years ago in AVEVA™ PI Server / System Management 0 No status

Dynamic inventory of PI System components

Provide a way to have an online, dynamic inventory of installed PI System components, especially interfaces.
Guest over 3 years ago in AVEVA™ PI Server / System Management 0 No status

Remove the PI Interface Configuration Utility (PI ICU) from the PI System Management Tools (PI SMT) install kit

PI System Management Tools is more of a client-side program, so it does not make sense for it to be packaged with a server-side program like the PI Interface Configuration Utility. This increases the size of the install kit, increases the extracti...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / System Management 1 No status

PI DataLink Time Filtered Function should be as accurate as the results given by an equivalent Analysis.

For example: Time Filtered in DataLink with: 'sinusoid>98' Start Time: Y End Time: T Should give the same result as: TimeGT('sinusoid','y','t',98)
Guest over 3 years ago in AVEVA™ PI DataLink™ / Functions 0 Declined

Populate child attribute in Asset filter Search - Attribute to display

Child attributes are populated in the Attribute value filters section of the Asset filter search but have to be entered manually in the Attributes to display section. Users not familiar with the AF syntax or AF hierarchy have trouble entering/find...
Marc-Olivier Baillargeon over 2 years ago in AVEVA™ PI DataLink™ / Functions 0 No status

Ability to use multiple attribute filters with an 'OR' condition with Explore Events and Compare Events functions

Attribute value filters in the Explore Events and Compare Events functions in PI DataLink are 'AND' conditions as documented in the doc topic Explore Events task-pane reference . It would be helpful to use multiple filters with an 'OR' condition i...
Zoe Altenberg about 2 years ago in AVEVA™ PI DataLink™ / Functions 1 No status

PI Message Logs should be forwardable

Some networks with PI interfaces are not accessible to the PI Server management team, it would be very helpful if the PI Message Subsystem could forward copies of PI Messages to an associated PI server, so that we could look at the interface messa...
jdjohnstn over 3 years ago in AVEVA™ PI Server / System Management 0 Declined

Integrate PSH data with enterprise monitoring tools

I'd like PSH to integrate with Enterprise Monitoring Tools such as Splunk or MS SCOM so that I can see PI System Health data in one console (with my enterprise monitoring solution).
Guest over 3 years ago in AVEVA™ PI Server / System Management 1 Declined

in point builder remove the ability to delete pi point on right click.

Remove the ability to delete pi point on right click in PI SMT Point Builder Put this function elsewhere
Guest over 3 years ago in AVEVA™ PI Server / System Management 10 No status

Pre-installation system wide compatibility check

As a system administrator, I would like a comprehensive tool to validate system and version compatibility across my entire PI system.  When performing upgrades / adding components to my PI infrastructure, it takes considerable time to comb th...
Guest over 3 years ago in AVEVA™ PI Server / System Management 1 No status