To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 75

MarkArchiveGaps tuning parameter description should be more descriptive

The description for the MarkArchiveGaps tuning parameter for a value of 2 is unclear. A user might interpret: 2 - Gap markers only when there is an actual gap between two consecutive archives. to mean that markers are shown when a tag does not h...
Guest over 3 years ago in AVEVA™ PI Server / System Management 0 No status

Dynamic inventory of PI System components

Provide a way to have an online, dynamic inventory of installed PI System components, especially interfaces.
Guest over 3 years ago in AVEVA™ PI Server / System Management 0 No status

Remove the PI Interface Configuration Utility (PI ICU) from the PI System Management Tools (PI SMT) install kit

PI System Management Tools is more of a client-side program, so it does not make sense for it to be packaged with a server-side program like the PI Interface Configuration Utility. This increases the size of the install kit, increases the extracti...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / System Management 1 No status

displayname/localname for identifier that excludes namespace and data type

Example: OPC UA Server 'Name': 2.0:W-HVAC-AC-1-IO!Wtot Namespace: 2 Datatype: 0 Identifier: W-HVAC-AC-1-IO!Wtot OPC UA Server 'DisplayName': W-HVAC-AC-1-IO!Wtot OPC UA Adapter {Identifier} returns: 2.0:W-HVAC-AC-1-IO!Wtot Required stream name: W-H...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Enable Adapter for OPC UA to use the Pub/Sub method

Pub/Sub is proposed to be a more efficient and scalable method of transferring data using OPC UA. Allowing the adapter to access data in this way would increase the options for data collection, and allow the OPC UA adapter to be used in many more ...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Adapter for OPC UA should send the previous value when it has been with the same value for a long time

"This enhancement request proposes a solution to address the issue of data interpolation between two values far apart in time in adapter data collection. The suggestion is to include the value right before the new data point, ensuring the fidelity...
Fabio Dani over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

in point builder remove the ability to delete pi point on right click.

Remove the ability to delete pi point on right click in PI SMT Point Builder Put this function elsewhere
Guest over 3 years ago in AVEVA™ PI Server / System Management 10 No status

Pre-installation system wide compatibility check

As a system administrator, I would like a comprehensive tool to validate system and version compatibility across my entire PI system.  When performing upgrades / adding components to my PI infrastructure, it takes considerable time to comb th...
Guest over 3 years ago in AVEVA™ PI Server / System Management 1 No status

Sizing sheet should include at least minimal support for AF Audit Trail

Currently there is not a single hint nor guidance on the impact of the Audit Trail in the sizing sheet, while the Audit Trail can have a major impact on the storage requirements.
Guest over 3 years ago in AVEVA™ PI Server / System Management 0 No status

Align the Archive_AutoArchiveSize and Minimum Archive Size to be based on Tag Count, not Record Number Count

Schedule data archive shifts occur and create archive files based upon a Minimum Archive Size calculation. This calculation is based upon the total count of record numbers. When large amounts of tags are deleted, the total number of tags is reduce...
Guest over 3 years ago in AVEVA™ PI Server / System Management 0 No status