To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 273

Add 'Stopped by user' status for analysis

As an AF administrator, I would like to understand the difference between an analysis that is stopped by an end user, or an analysis that has stopped but should likely be running. Currently when an analysis is stopped, we do not know if this is ex...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Allow PIWorld and piusers to be deleted

Nobody should be using the "PIWorld" PI Identity or the "piusers" PI Group. The most that we can do at the moment is disable them. It would be much better if we can just delete them and never look back.
Kenneth Barber over 3 years ago in AVEVA™ PI Server / System Management 2 No status

Support for Windows event logging

As a system administrator, I need to integrate PI System logging into my SEIM, so that I can manage PI System events consistent with other applications in a centrally managed system. Most PI System applications leverage the Applications and Serv...
Guest over 3 years ago in AVEVA™ PI Server / System Management 1 No status

Allow PI Collective members to be permanently represented by alias names

For example, in PI SDK, when viewing "member setup" for a PI Collective, it is desired for the names of the members to always be represented as a DNS alias or SDK alias. At the outset of PI Collective creation, in PI Collective Manager for instanc...
Ryan Biggins over 1 year ago in AVEVA™ PI Server / System Management 0 No status

Allow adding naming conventions

Administrating large systems require providing naming standards (for example when implementing international standards like ISA95) for various system elements: PI Point, AF DBs, Elements, Templates and so on. AVEVA software could support naming co...
Czuprynski over 1 year ago in AVEVA™ PI Server / System Management 0 No status

Remove requirement for shared volume for PI Analytics and PI Notifications high availibility

Our corporation has highly available PI in a number of sites. Our PI infrastructure is highly available except for Analytics and Notifications. The requirement for a shared volume for the failover cluster is not supported. We can support the failo...
Nathan Anderson 10 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Option to not have Value Retrieval Method and TagTot "fill in the gaps"

When taking a Total using Value Retrieval Method (configured in AF Attribute) or using TagTot (an AF Analytics function), PI will "fill in" gaps in the data. For instance, if you have a Float32 tag that is reading good for half of the day and then...
taterhead247 over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Better Error Handling and Reporting

On more than one occasion, have missed several days worth of calculations with no indication of a problem. There were errors in the log, however there is nothing monitoring this log. The analytics service was running, but not actually doing anythi...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Event frames start trigger on trigger condition change

I would like to be able to define start trigger that fires a e new event frames only if the start condition changes. I mean: - Start trigger: 'Equip Status' = "ON" - End trigger: 'Equip rpm' >= 1000 I would like that the event start is triggere...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 4 No status

XOR operator for expression analyses

AF (and PE) expressions currently have AND and OR operators. These work either logically or (if both operands are integer) in a bitwise fashion. There should also be an XOR operator that works the same way, to avoid the messy construct (A AND NOT ...
tinklerj over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status