To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 180 of 5259

Batch interfaces keeping merged child operation EventFrames open until the parent Operation EventFrame has been closed.

Currently for batch interfaces using the /MUP parameter, child operation event frames might be reopened and closed multiple times until the last operation event frame closes and the child event frame is closed for good. For example with UnitProced...
Guest almost 2 years ago in PI Interfaces / Batch Interfaces 0 No status

EMDVB Data Type Enhancement

Please include option in the DeltaV EMDVB interface that can handle the timestamp format used with .evt files. Currently, if in the interface a trigger is used with a property, the timestamp format in the .evt file is retained, which cannot be sto...
Gary Moore 12 months ago in PI Interfaces / Batch Interfaces 0 No status

Restrict Batch interface from creating Event Frames using illegal characters

The PI Interface for Rockwell FactoryTalk Batch in processing evt files used a hexadecimal character of 1f in the generation of an event frame. This results in an error when attempting to export the event frame in an xml output.
Nathan Skitt about 1 year ago in PI Interfaces / Batch Interfaces 3 No status

Enhance element creation to use user defined element templates

The interface can automatically create an element at each level of event frames, but the elements do not derive from a template and there is no way to specify any attributes on the element. The enhancement request is to create elements that are ba...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 Declined

PI EMDVB Interface - Rename Parsed Files

PI EMDVB Interface - Rename Parsed Files.  Files that get renamed to .999 is no longer available with PI EMDVB.  This file renaming feature was very useful from a system maintenance perspective.  We would easily remove .999 from the...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 Declined

PI EFGen 4.1+ has limited recovery capabilities

Up to PI EFGen 4.0, we were able to backfill OOO Event Frames by simply inputting the start and end time of the corresponding period. Since 4.1, this must be done in a per-event basis, since larger time ranges are modified so that RST matches the ...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 1 No status

PI Adapter for GE e-terrahabitat/HabConnect

We need a new robust product to support data transfer between GE e-terrahabitat/HabConnect and PI. This product would need to support the following: Highly available remote management/deployment multiple instances on a single node (to support larg...
GaryYegiazaryan over 2 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Adapter for RDBMS to support multiple rows with same "Timestamp" colum as IndexColumn

As of version 1.x, with the IndexColumn being specified in the dataselection, the Adapter will require that each row in the source Database to have its own unique timestamp. If there are multiple rows with the same timestamp, first value with the ...
Ee Sheing Lee over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 1 Tell us more

Support System States for the Adapter for Azure Event Hubs

The data passed through the Adapter for Azure Event Hubs can be very dynamic in its configuration. It would be useful to be able to send system states to indicate bad data, and possibly the nature of that bad data. In the same way that interfaces ...
Mike Horrocks about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 2 No status

displayname/localname for identifier that excludes namespace and data type

Example: OPC UA Server 'Name': 2.0:W-HVAC-AC-1-IO!Wtot Namespace: 2 Datatype: 0 Identifier: W-HVAC-AC-1-IO!Wtot OPC UA Server 'DisplayName': W-HVAC-AC-1-IO!Wtot OPC UA Adapter {Identifier} returns: 2.0:W-HVAC-AC-1-IO!Wtot Required stream name: W-H...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status