To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 122 of 5197

Support for 'Short' data type for PI AMI Interface for Itron OpenWay Collection Engine

The 'Short' data type of a Register Value is not currently compatible with the interface. The user guide does not explicitly mention 'Short', and it denotes that the supported PI Point types are Float32, Digital, String. Of which, none are technic...
Robert Reed over 2 years ago in PI Interfaces / Other Interfaces 0 No status

Table-Valued Function

Currently it is not possible to define filter definitions for Table-Value functions.With DataLink I'm able to define to build an average for a process value by using a defined filter method. e.g. calculating an average current of an engine while t...
Christian Benitz about 3 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 0 No status

Add new feature to allow PI Citect Interface to use the syntax [] to select an element of an array.

The ability to address parts of an array via the Citect API will cut down the number of Citect variables that need to be created so that they can be collected by the PI Citect Interface. Allow the use of syntax [] to select an element of an array ...
BrentonC about 3 years ago in PI Interfaces / Other Interfaces 0 No status

Add support for unit conversion

Please add a "Canonical UOM Per UOM" or "UOM Per Canonical UOM" column (not necessarily with those exact names) to the UnitOfMeasure table. This column would contain the conversion factor needed to convert between the UOM and the canonical UOM, si...
Kenneth Barber over 3 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 0 No status

Add RTQP PI SQL support for parameter type cast

PI DAS (RTQP Engine) 2018 SP3 Patch 1 lacks support for type casting input parameters of a table valued function. For example. this simple example fails to create a table valued function: CREATE FUNCTION [MOMS].[fact].[getInstrumentOperationalDat...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 0 No status

Add RTQP PI SQL support for default value of function parameter

The current version of PI DAS (RTQP Engine) does not support the definition of default values for table-valued function parameters. This is a rather bleak omission, in my view. For example, the following will fail to create the table-valued functi...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 0 No status

OPC HDA Interface: Add a health digital tag for each scan class to indicate when HR is occurring versus realtime for that scan class

Add health digital tags for each scan class to indicate when HR is occurring versus realtime for that scan class. This would indicate when the interface is performing HR for the scan class and when it switches to realtime collection.
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Always use arc_append when archiving data using SIPowerTG interface

This is the interface from the Siemens Power TG EMS system. The problem is with the saving of Alarm and Event text messages. There are instances when the data files are produced out of order. When data is sent out of order the interface seems to g...
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Offset timestamps send by  PI Interface for  Environmental Systems Corp StackVision

Please allow the option to offset data sent by the interface. This will enhance the ability to compare time stamps between data sources and the PI Server  in different timezones.
Guest over 3 years ago in PI Interfaces / Other Interfaces 2 No status

Name support in BACnet Network Discovery Tool

Can you remove the restriction to use only an IP address in the BACnet Network Discovery Tool?  The interface will correctly load and poll tags to a network device referenced by name instead of IP, however the Discovery Tool has the limitatio...