To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 493 of 5193

EFGEN multi language support for event frame name

Hi, Existing EFGEN does not seem to support multi language (Double bytes characters) inputs for Event frame name. This result in the event frames names are being recorded in English char only. Would it be possible to implement the multi-langua...
Guest over 3 years ago in PI Interfaces / Other Interfaces 1 Declined

Allow the data type of PI Points to be set manually with PI connector for OPCUA

[Background]We know that when use PI Connetor for OPCUA, the data type of the PI Point is synchronized with the OPC server settings. But we would like to set deferent one.e.x.) -Datatype of OPC Server tag : "String" -Data type wanted to be set for...
Guest over 1 year ago in PI Connectors / PI Connector for OPC UA 0 No status

Native Python connector for Linux

I'm a Lead Data Scientist. I've built the MLOps pipeline for Machine Learning (ML) models. To train a model, I need at least 2-3 years of data at high frequency. While the entire data sciences community relies heavily on Python, I'm amazed to see ...
Guest 11 months ago in PI Connectors / New PI Connector Request 0 No status

Allow the BACnet Connector to handle responses with an LVT that does not match the request

Currently the BACnet Connector expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Connector cannot parse the data in the response. For example: Request from Connector, LVT=1 Re...
Nico Cha almost 2 years ago in PI Connectors / PI Connector for BACnet 0 No status

Separated output folder for different data source

I am interested to be able to configure for each data source separately output folder where processed data files are stored. Currently, all processed data files are moved to one OUTPUT folder and afterwards zipped. I would like to have this functi...
Guest almost 3 years ago in PI Connectors / PI Connector for UFL 0 No status

WIS support for TCP Response interface

If trusts are disabled in Data Archive, the TCP Response Interface will generate a logon error every time it performs a TCP request (https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=000032778). The interface should be updated, ...
mose almost 2 years ago in PI Interfaces / Other Interfaces 0 Evaluating

PI System Connector: Allow subset of event frames to be replicated

Currently you only have the ability to replicate ALL event frames and only if you want to replicate the entire AF database. We have one main AF database with many different types of event frames; however we do not want to replicate them all. It wo...
Rebekah_Wilson almost 2 years ago in PI Connectors / PI System Connector 1 No status

Support of EEC (Elliptic Curve Digital Signature Algorithm ) Certificates

Make the Connector, DCM and Relay support EEC (Elliptic Curve Digital Signature Algorithm) Certificates in future versions. Admin Certificates can be exchanged manually usinmg netsh, but the usage of RSA encrypted certificates is required here.
Julian Baur almost 3 years ago in PI Connectors / General 0 No status

Permissions to discover and create tags only

Create the ability to give users permissions to discover and create tags only in PI Data Collection Manager. We were able to give users the ability to only create tags when using OPC DA interfaces, but we can no longer do this with PI DCM. This se...
David Sugden about 1 year ago in PI Connectors / PI Connector for OPC UA 0 No status

PI Connectors/Relay/DCM be able to use GMSA accounts

When installing any PI Connector / Relay / Data Collection Manager, I am unable to use a GMSA account as part of the install. I'm able to go change the service afterwards but the service account requires a password in the installer (which there is...